5

2-2 Electrical Specification

Analog test range :DCV/ACV:2V,200mV

DCA: 20mA

Accuracy

(at 23℃±5℃,below 80%RH)

DC

è(±1%rdg+3dgts)

AC

è(±1%rdg+5dgts) at (50~450Hz)

Resolution

200mV/2V range is 0.1mV/1mV

20mA range is 0.01mA

A / D Sample Rate :2.5 times/sec

Power Source

6 pcs 1.5V,# 3 battery or 9V, DC adaptor

(inside negative, outside positive)

Battery Life

:Approx. 100 hours (without printing)

Printer

Thermal printer (EPL1902 of Panasonic)

MEMORY

60000 records (up to 130000 records)