Operation way :

Press

INTV

+ Power ON into Process Transducer (4 - 20 mA) mode.

First of all, setting Ref1 “ MAX ” reference value (the “MAX” symbol will be flash),

then press button to input “ MAX ” reference

0.001 ~ 9999, press

RECORD

=

button and wait for speaker sound. Then

the process transducer (4 - 20mA) mode setting is success.

“ LCD ” display value:

Ref1- 0

16

´

(A/D Reading-4) = “ LCD ” display value

Available for (4mA ~ 20mA) transducer only.

4. BATTERY & FUSE REPLACEMENT

4-1 Battery Check & Replacement

1. As battery power is not sufficient, the

, will be shown on LCD

replace with six new 1.5V batteries is required.

2. a). Disconnecting test leads.

b).Turning off multimeter with screw-driver.

c). Open battery cover.
d). Replace the batteries

e). Cover and secure the battery cover.

4-2 Fuse Replacement

a). Disconnecting test leads.

b). Turn off multimeter.

c). Open fuse cover with screw-driver.
d). Remove old fuse and replace with new fuse.

e). Cover and secure the fuse cover.

Only 5ψ

×

20mm fast blow type fuse is allowable.

4-3 Note

To prevent electrical hazard or shock, turn off multimeter and disconnect
test leads before removing any cover.

5. DATALOGGING

0 1/2/3

4/5/6

7/8/9