7

IMPORTANT: On plush and new carpets, stuffing may occur
due to excessive fuzz and loose cuttings in the carpet.
Stuffing could occur for the first few cleanings until all the
loose material is removed. Due to the high efficiency of the
cleaner, many older carpets will cause stuffing when the
cleaner is first used on them.

NOTE: If the “Stuffing or Blockage” actions do not correct the
problem, contact an ORECK authorized service center or call the
customer service center at: 0845 603 0153.

Your ORECK XL vacuum
cleaner has a special
Oreck Fresh Air

®

tab

pocket. This pocket is
located inside the outer
bag in the area where the
disposable paper bag
attaches to the intake
tube. Insert tablet in
pocket.

Using An Oreck Fresh Air

®

Tab

WARNING: Unplug cord from electrical
outlet before servicing.

S

tuffing or

B

lockage

Under certain conditions it is possible to stuff or block the intake
tube and the lower tube assembly. If your vacuum cleaner does
not pick up properly, or makes unusual noise and the outer bag
does not fluff up or balloon open, follow the following steps:

1. Check for blockage at the

mouth of the intake
opening. See illustration A.
If there is blockage, remove
it with long-nose pliers, a
screwdriver or coat hanger.
If you can not reach the
blockage, remove
baseplate. See illustration B.

2. If the blockage is not at the

base, remove lower tube.
See illustration C. Unhook
retainer spring, releasing
bottom of bag. Twist lower
collar counterclockwise to
slide up. Pull tube out of
base. Check for blockage.
If blockage is in the tube,
remove with a coat hanger.

3. If tube is not blocked, look

into fan housing. See illus-
tration D. Remove debris
with long-nose pliers, a
screwdriver or coat hanger.

4. To reassemble, check O-ring

on tube, and replace if
damaged. Vacuum will not
operate properly without the
tube O-ring. Slide O-ring to
approximately 2" from base
of tube. Replace tube by
first lining up slot at base of
tube with inner tab inside
fan housing. Then reinsert
tube and push down until
the tube is seated. Make
sure O-ring is in place
against fan housing
opening. Replace and
tighten collar until collar
locking tabs are locked in
place. See illustration E.
Make sure collar is not cross
threaded on housing.

5. Many times blockage occurs

due to a full dust bag
causing dirt to back down
the air flow system. When
that happens, the blockage
will be at the top of the
system, starting in the area
where the dust bag connects
to the connector assembly.
See illustration F.

Intake Opening

B

C

Retainer

Spring

Intake Opening

A

D

O-ring

Fan

Housing

E

F

Connector

Deflector

Opening

Bulb Replacement

Remove lamp housing by
removing two (2) screws in
the the top of the lamp
housing. Pull burned out
bulb from holder and
replace with new bulb. Use
only Oreck replacement
parts. Reassemble lamp
housing by replacing two
screws in the top of the
lamp housing. WARNING:
Unplug cord from electrical
outlet before servicing.

Advertising