Trouble shooting tips, Page 50, Symptom probable cause action to take – Orion Car Audio HCCA 225R User Manual

Page 50

Advertising
background image

page 50

TROUBLE SHOOTING TIPS

SYMPTOM

PROBABLE CAUSE

ACTION TO TAKE

No output

Low or no remote turn-on input

Check remote turn-on voltage output at amplifier and

fix as needed

Fuse blown

Check power wire integrity and check for speaker shorts.

Fix as needed and replace fuse

Power wires not connected

Check power wire and ground connections and fix or

replace as needed

Audio input not connected

Check RCA connections and fix or replace as needed

Speaker wires not connected

Check speaker wires and fix or replace as needed

Speakers are blown

Check system with known working speaker and fix or

replace speakers as needed

Audio cycles on

Thermal protection engages

Make sure there is proper ventilation for amplifier and improve

and off

when amplifier

Heatsink ventilation as needed

temperature exceeds 90°C (190°F)

Loose or poor audio input

Check RCA connections and fix or replace as needed

Loose power connections

Check power wire and ground connections and fix or replace

as needed

Distorted output

Amplifier level sensitivity set too

Readjust gain. Refer to Adjusting the sound of the system

high. Exceeding maximum

section of this manual for detailed instructions

capability of amplifier

Impedance load to amplifier

Check speaker impedance load, if below 2

stereo or 4

mono

too low.

Rewire speakers to achieve a higher impedance

Shorted speaker wires

Check speaker wires connections and fix or replace as needed

Advertising