D - 4

2.1

Engine Menu Group

In the Engine Menu Group, following items may be set.

(1) Print Position

Display

Print Position

Setting item

Correct print start position.

Setting range

–4.00 mm ~ +3.5 mm

F/W default

0.00 mm

(2) LED Head Drive Time

Display

LED Head Marking No.

Setting item

Adjust LED head marking time.

Setting range

–37 ~ 505 – 545

F/W default

155 – 167

(3) LED Head Width (OKIPAGE 6e)

Display

LED Head Width

Setting item

Select number of LED Head dot numbers.

Setting range

Full (2560 dots)/Narrow (2496 dots)

F/W default

Full

(4) Setting

Display

Setting

Setting item

Adjust transfer current intensity

Setting range

–1/0/+1

F/W default

0