Ordering information, Mechatrolink-ii-compatible position control units, Mechatrolink-ii-compatible motion control units – Omron CPU Unit CJ2 User Manual

Page 35: Serial communications units, Ethernet/ip unit

Advertising
background image

35

MECHATROLINK-II-compatible Position Control Units

■

Unit

classification

Product name

Specifications

No. of

unit

numbers

allocated

Current

consumption

(A)

Model

Standards

5 V

24 V

CJ CPU
Bus Units

MECHATROLINK-II-
compatible
Motion Control Units

Control commands executed by MECHATROLINK-II
synchronous communications.
16 axes max.
Direct operation by ladder programming.
Control mode: Position control, speed control,
or torque control

1

0.36

—

CJ1W-NCF71

UC1, CE

MECHATROLINK-II-compatible Motion Control Units

■

Unit

classification

Product name

Specifications

No. of

unit

numbers

allocated

Current

consumption

(A)

Model

Standards

5 V

24 V

CJ CPU
Bus Units

MECHATROLINK-II-
compatible
Motion Control Units

Position, speed, and torque commands by
MECHATROLINK-II
32 axes max. (Physical axes: 30, Virtual axes: 2)
Motion control language

1

0.6

—

CJ1W-MCH71

UC1, CE

Note: The CJ1W-MCH71 requires the space of three Units (but just one unit number). A maximum of 10 Units can be mounted

on a single CJ-series Rack, up to three CJ1W-MCH71 Motion Control Units plus one other Unit can be mounted per Rack.

Serial Communications Units

■

Unit

classification

Product name

Specifications

No. of

unit

numbers

allocated

Current

consumption

(A)

Model

Standards

Communications

Interface

Communications functions

5 V

24 V

CJ CPU
Bus Units

Serial
Communications
Units

1 RS-232C port and
1 RS-422A/485 port

The following functions can be
selected for each port:
Protocol macro
Host Link
NT Links (1:N mode)
Serial Gateway (See note 1.)
No-protocol (See note 2.)
Modbus-RTU Slave (See note 3.)

1

0.38

(See

note 4.)

—

CJ1W-SCU41-V1

UC1, N, L,
CE

2 RS-232C ports

0.28

(See

note 4.)

—

CJ1W-SCU21-V1

2 RS-422A/485 ports

0.38

—

CJ1W-SCU31-V1

Note 1. The Serial Gateway function is enabled only for Serial Communications Units of unit version 1.2 and later.

2. The no-protocol function is enabled only for Serial Communications Units of unit version 1.2 and later (and a CPU Unit of unit version 3.0 or later is also required).

3. The Modbus-STU Slave function is enabled only for Serial Communications Units of unit version 1.3 and later.

4. When an NT-AL001 RS-232C/RS-422A Conversion Unit is used, this value increases by 0.15 A/Unit. When a CJ1W-CIF11 RS-422A Conversion Unit is used, it increases by 0.04 A/Unit.

EtherNet/IP Unit

■

Unit

classification

Product

name

Specifications

No. of

unit

numbers

allocated

Current

consumption (A)

Model

Standards

Communications

cable

Communications

functions

Max.Units

mountable

per CPU

Unit

5 V

24 V

CJ CPU
Bus Units

EtherNet/IP
Unit

STP (shielded
twisted-pair) cable
of category 5, 5e, or
higher.

Tag data link
message service

8

(See note)

1

0.41

—

CJ1W-EIP21

UC1, N, L,
CE

Note: Up to seven EtherNet/IP Units can be connected to a CJ2H-CPU

-EIP CPU Unit.

Ordering Information

Advertising