10 specificati, Specifications, Suggestion #4 – Outlaw Audio 200 M-Block User Manual

Page 10: Suggestion #5

Advertising
background image

10

Outlaw Audio

Owner’s Manual

11

Model 200 M-Block Power Amplifier

Owner’s Manual

Warning: if you suspect that the grounding system in your home’s electrical
wiring is causing the hum problem, it is important that you do not make
any changes to the wiring yourself. Only a licensed electrician should
make any changes to household wiring, and they must be made in full
compliance with all local building, safety and electrical codes.

Suggestion #4:

Faulty earth grounds may also cause hum in your home’s electrical system. In
the past, cold water pipes were often used for the earth ground, so it is important
to make sure that your ground connection is still valid and has not become
loose or corroded. The cold water pipe method may no longer be valid in some
locations due to requirements that the water meter be isolated from the water
mains with a length of PVC pipe, thus interrupting the ground circuit. The
safest, and most reliable, approach may be to provide your own ground. This
can be accomplished by having a licensed electrician drive at least five feet
of copper-jacketed steel grounding rod into the earth, and using that for your
grounding connection.

Suggestion #5:

If you have hum in your video display device (bars that roll up through image
at 12-14 second intervals), this may be related to hum you also experience in
your audio system. The previous suggestion tips may help with this also. If not,
try isolating the ground in the projectors video signal cable with a base-band
video isolation transformer, such as the Jensen VB-1BB.
If the hum persists after all of the above suggestions have been tried, contact
the Outlaw Audio customer service department for assistance.

Specifications

Specifications

Power Output 200 watts @ 8 ohms, 20 Hz 20 kHz, <0.05% THD

300 watts @ 4 ohms, 20 Hz 20 kHz, <0.05% THD

THD Signal to Noise 100 dB (un-weighted)

Trigger Input 6-35V DC 4mA

Operating Mode Class G/AB

Input Impedance >10K Ohms

Gain +27dB (1.7V sensitivity) for full output

Input Connector RCA Jack

Output Connectors Five-Way binding posts

Power Consumption 600 watts maximum; <3 watts standby

Weight 18 pounds /8.165 Kg.

Dimensions (H/W/D) 1.5” x 17” x 11.5”/40mm x 430 mm x 330 mm

Note: Due to our policy of continual improvement, all specifications are subject
to change without notice or liability to upgrade previously shipped units to current
specifications or standards