Oki ML520 User Manual

Page 40

Advertising
background image

Page: 24

Service Guide ML520/521

Chapter 2 Principles of Operation


LSI

Location 04B: MSM79VO35

Detects the output of the two-phase sensor on the DC space motor to control the motor drive phase.

Transmits and receives serial data to and from the printhead based on the dot timing (which is derived
from the space motor speed).

Controls the external interface. The LSI is connected to the MPU.

Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)