3 configuration command string – Ovation Software Label Printer User Manual

Page 33

Advertising
background image

Printing Labels

Ovation

2

25

2.3

Configuration Command String

The configuration command string sets the operating parameters of
the printer. The command strings are described below.


<STX>KDwxy

<CR>

where w:
Bit # Function

Value

0-2

Baud Rate

0=9600*, 1=600, 2=2400, 3=19200, 4=4800, 5=N/A,
6=1200, 7=9600 Test Mode

3

Word Length

0=8 bits*, 1=7bits

4&5

Unused

Set to 0

6

Always 1

Set to 1

7

Always 0

Set to 0


where x:
Bit # Function

Value

0

Print Method

0=direct thermal*, 1=thermal transfer

1

Present Sensor

0=not equipped, 1=equipped

2

Alternate Char.
Set

0=standard*, 1=main frame

3

Cutter

0=disabled*, 1=enabled

4&5

Unused

Set to 0

6

Always 1

Set to 1

7

Always 0

Set to 0


where y:
Bit # Function

Value

0&1

Paper Type

0=gap*(edge), 1=reflective, 2=continuous (3")

2

Unused

Set to 0

3-5

Unused

Set to 0

6

Always 1

Set to 1

7

Always 0

Set to 0

* = factory defaults


Example: <STX>KD @A@

<CR>

@

Sets the printer to: 9600 baud; 8 bit word length/no parity.


A

Sets the printer to: thermal transfer; no present sensor;
standard character set; no cutter.

Advertising