Power up led test, Operational modes, D. distant lobe extension – Omnitron Systems Technology 4/16 Token Ring Fiber Converter OmniHawk User Manual

Page 5: E. other applications

Advertising
background image

The bottom left LED is yellow / red, the remaining three LEDs are yellow /
green. The meaning of the LEDs are shown on the cover of the OmniHawk™
and in the tables below.

POWER UP LED TEST

ALL LEDS

MEANING

Yellow for 1/2 second then Green or Red

or 1/2 second

Self Test OK

Any other behavior

Failed Self Test, Call Technical Support

The OmniHawk™ performs a self test every time power is newly applied.

OPERATIONAL MODES

FIBER READY

(top left)

MEANING

COPPER READY

(top right)

MEANING

GREEN

Data received from
fiber

GREEN

Data received from
copper

Off

No data is being
received from Fiber

OFF

No data is being
received from copper

POWER /

ERROR (bot.

left)

MEANING

INSERT STATUS

(bot. right)

MEANING

YELLOW

Power is on

GREEN

The fiber optic and
copper interfaces have
both actively inserted

RED

An attachment error
occurred

FLASHING

GREEN

Still attempting to
insert

OFF

Insertion is not being
attempted

3

C. Hub Ring Out (RJ45) to distant hub Ring In (RJ45)

Application C shows the Ring Out of one hub connected to the Ring In of
another hub via a pair of OmniHawk™ converters. Note that the cable from
the second OmniHawk™ to the Ring In is a crossed cable.

D. Distant Lobe Extension

Application D shows a distant hub in lobe extension via a pair of OmniHawk™
converters. In this configuration a standard CAT-5 cable connects the ex-
tended hub to the first OmniHawk™, fiber optic cables connect the two
converters, and another standard CAT-5 patch cable connects the second
OmniHawk™ to the target hub.

E. Other Applications

The above examples show the most common applications of the
OmniHawk™. Your network may require an application not listed here. The
configuration you need will be supported by the OmniHawk™ as long as
the correct cable is used. The fiber optic cables will always be the same.
The table below will guide you in selecting the proper copper cables, media
filters, and connector adapters.

OST PART #

CONNECT FROM

CONNECT TO

9300-P45

OmniHawk™ RJ45

Lobe, RJ45

OmniHawk™ RJ45

Ring Out, RJ45

9301-P45X

OmniHawk™ RJ45

Ring In, RJ45

OmniHawk™ RJ45

Workstation, RJ45

5700-CMF &
9301-P45X

OmniHawk™ RJ45

Workstation, DB9(if not directly
attaching the OmniHawk™ to the
workstation)

5701-IP45 &
9300-P45

OmniHawk™ RJ45

Lobe, IBM Data Connector

OmniHawk™ RJ45

Ring Out, IBM Data Connector

5701-IP45 &
9301-P45X

OmniHawk™ RJ45

Ring In, IBM Data Connector

9310-IF9

OmniHawk™ DB9

Ring In, IBM Data Connector

9311-IF9X

OmniHawk™ DB9

Ring Out, IBM Data Connector

OmniHawk™ DB9

Lobe, IBM Data Connector

9320-FM9

OmniHawk™ DB9

Workstation, DB9(if not directly
attaching the OmniHawk™ to the
workstation)

10