Specifications

PLC model name

Model number

CPM1-10CDR/20CDR- /CPM1A-10CD/20CD/30CD/40CD -

CPM2A-30CD/40CD/60CD -

CPM2C-10/20 -

C200HE-CPU32(-Z)(See note.)/ CPU42(-Z)

C200HG-CPU33(-Z)(See note.)/ CPU43(-Z)/CPU53(-Z)(See note.)/ CPU63(-Z)

C200HX-CPU34(-Z)(See note.)/CPU44(-Z)/CPU54(-Z)(See note.)/CPU64(-Z)/CPU65-Z/CPU85-Z

CS1G-CPU42(-V1)/ CPU43(-V1)/ CPU44(-V1)/ CPU45(-V1)

CS1H-CPU63(-V1)/CPU64(-V1)/CPU65(-V1)/CPU66(-V1)/CPU67(-V1)

CV500-CPU01-V1/CV1000-CPU01-V1/CV2000-CPU01-V1/
CVM1-CPU01-V2/ CPU11-V2/ CPU21-V2

C Series: CPM1

RS-232C or RS-422A adapter connected to peripheral port

RS-232C connector (9-pin)

RS-232C connector (9-pin)

C Series: CPM2A

C Series: CPM2C

CQM1-CPU21/CPU41-V1/CPU42-V1/CPU43-V1/CPU44-V1

CQM1H-CPU11/CPU21/CPU51/CPU61

C200HS-CPU21/CPU23/CPU31/CPU33

C Series: CQM1

C Series: CQM1H

C Series: C200HS

C Series: C200HE (-Z)

C Series: C200HG (-Z)

C Series: C200HX (-Z)

CS Series: CS1G

CS Series: CS1H

CVM1/CV Series:
CV500/1000/2000 or
CVM1

Note: The C200HW-COM02, C200HW-COM04, C200HW-COM05, or C200HW-COM06(-V1) Communications Board is required.

Connections through CPU Unit/Host Link

Standard Models

Communications connectors include both a peripheral port and
RS-232C port (branching possible through CPM2C-CN111
Conversion Cable).
Used as separate peripheral and RS-232C ports through CS1W-
CN114/118 Conversion Cable.

RS-232C connector (9-pin) (Only peripheral port for CQM1H-CPU11)

RS-232C connector (9-pin, selectable)

RS-232C connector (9-pin)

RS-232C connector (9-pin, selectable)

Options

Specifications

Model number

Model name

RS-422A
Adapter

Video Input
Unit

Special Cable for the Console

Anti-reflection Sheets
(5 surface sheets)

NS12/10

Protective Covers
(5 pack)
(anti-reflection coating)

Protective Covers
(5 covers included)
(Transparent)

Memory Card

Memory Card Adapter

Battery

Bar Code Reader
(Refer to the Catalog for details.)

NS12/10

30 MB

Inputs: 4 channels
Signal type: NTSC/PAL

Input channels: 2 video
channels and 1 RGB
channel (See note.)
Signal mode: NTSC/PAL

For Controller Link
Communications

NS-CA001

NS-CA002

F150-VKP (2m)

Controller Link
Interface Unit

NS-CLK21

F150-VKP (5m)

NS12-KBA04

NS8

NS7-KBA04

NS5

NT30-KBA04

NS5

NT31C-KBA05

NS12-ATT01B

NS12-ATT02

NS12-KBA05

NS8

NS7-KBA05

NS12/10

NS5

NT31C-KBA05N

NS12-KBA05N

NS8

NS7-KBA05N

NS12-ATT01

NS8-ATT02

NS8-ATT01

HMC-EF372

64 MB

HMC-EF672

HMC-AP001

CJ1W-BAT01

V520-RH21-6

Note: One screen cannot display two video inputs simultaneously.

Transmission distance:
500 m total length
Note: Use this model when
connecting PT models without a V
suffix.
Note: PT models with a suffix of V
can also be connected.

NS-AL002

CJ1W-CIF11

Attachment

Transmission distance:
50 m total length
Note: Only PT models with a suffix
of V are connectable. Use the
NS-002 to connect models without
a V suffix.

(NT625C/631/631C Series to NS12/10 Series)

(NT625C/631/631C Series to NS12/NS10 Series) (Black)

(NT610C Series to NS12/10 Series)

(NT620S/620C/600S Series to NS8 Series)

(NT600M/600G/610G/612G Series to NS8 Series)

Sheet/Cover

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

CU, CE

Case color

Ethernet

Model number

Standards

Model
name

Specifications

NS12

12-inch TFT
800 x 600 dots

No

Yes

Ivory

Black

Ivory

Black

NS10

10-inch TFT
640 x 480 dots

No

Yes

Ivory

Black

Ivory

Black

NS8

8-inch TFT
640 x 480 dots

NS5

NS5
Hand-held

5-inch STN
320 x 240 dots

5-inch TFT
320 x 240 dots

5-inch
monochrome
320 x 240 dots

5-inch STN
320 x 240 dots

No

Yes

No

Yes

Ivory

Black

Ivory

Black

Ivory

Black

Ivory

Black

NS12-TS00-V2

NS10-TV00-V2

NS10-TV00B-V2

NS10-TV01-V2

NS10-TV01B-V2

NS8-TV00-V2

NS8-TV00B-V2

NS8-TV01-V2

NS8-TV01B-V2

NS5-SQ00-V2

NS5-SQ01B-V2

NS5-SQ01-V2

NS5-SQ00B-V2

NS12-TS00B-V2

NS12-TS01-V2

NS12-TS01B-V2

No

Yes

Ivory

Black

Ivory

Black

No

No

Yes

Ivory

Black

Black

Ivory

Black

NS5-TQ00-V2

NS5-MQ00-V2

NS5-MQ00B-V2

NS5-MQ01-V2

NS5-MQ01B-V2

NSH5-SQR001B-V2

NS5-TQ00B-V2

NS5-TQ01-V2

NS5-TQ01B-V2

Model number

Model name

Specifications

Cable
(See note 1.)

NSH5 Cables

NSH5 Wall-mounting Bracket

PT-to-PLC
Connecting Cable

Screen transfer cable for DOS/V

PT connection: 9 pins
PLC connection: 9 pins

Length: 2 m

Length: 5 m

USB Host Cable, cable length: 5 m

USB Host Cable, cable length: 2 m

XW2Z-S002

XW2Z-200T

XW2Z-500T

NS-US52 (5 m)

NS-US22 (2 m)

CS1W-CIF31

NSH5-422CW-10M

NSH5-232CW-3M

NSH5-232CW-10M

NSH5-ATT02

USB-RS-232C Conversion Cable,
cable length: 0.5 m

RS-422A cable (loose wires)
Cable length: 10 m

CX-One
FA Integrated
Tool Package
Ver. 1.1

The CX-One is an integrated
tool package that provides
programming and monitoring
software for OMRON PLCs and
components. The CX-One runs
on any of the following
operating systems:
Windows 98 SE, Me, NT 4.0
(Service Pack 6a), 2000 (Service
Pack 3 or higher), or XP.
CX-Designer version 1. is
included in the CX-One.
Refer to the CX-One catalog
(R134) for details.
(See note 2.)

OS: Window 98 SE, Me, NT 4.0
(Service Pack 6a),
2000 (Service Pack 3 or
higher), or XP.
The Ladder Monitor Software
is included.

1 license

1 license

CXONE-AL01C-E

3 licenses

CXONE-AL03C-E

10 licenses

CXONE-AL10C-E

30 licenses

CXONE-AL30C-E

50 licenses

CXONE-AL50C-E

NS-CXDC1-V1

The CX-Designer can also be ordered individually using the following model number.

CX-Designer
Ver. 1.

Specifications

Product name

Specifications

Model number

Face Plate Auto-Builder for NS

CSV tag files for LCB/LCU used in Face Plate Auto-Builder for NS

WS02-NSFC1-EV2

WS02-NSFC1-EV2 Face Plate
Auto-Builder for NS

NS Series

SYSMAC CS1

+

LCB/LCU

CX-Process Tool

(LCB/LCU programming software)

LCB/LCU program creation
(function block method)
CSV tag file output

CX-Designer

(NS screen creation software)

Editing created data
Creation of other required screens

Face Plate

Auto-Builder for NS

CSV tag file for
LCB/LCU

NS project file

Significantly reduces the engineering time required by
combining LCB/LCU and the NS Series.

Related Products

Automatic generation of control screens and tuning screens. Automatic
generation of NS screen data by the software from tag information created with
CX-Process Tool.
NS communications address allocation, ladder programs, etc., are completely
unnecessary.
Data that has been generated can be freely edited and processed by
CX-Designer (NS screen creation software).

NS Faceplate Auto-Builder upgraded to version 2.0.
Maximum number of automatically generated loops
increased from 32 to 100.
Automatic generation from the CX-Process projects
that use multiple nodes.
Automatic generation of detailed setting screens for
Line Segment programs.

Created screens are
easily transferred to the
NS by means of a
Memory Card or over
the network.

Superior environmental resistance
meets IP65F standards.

Flush surface construction is used for superior
environmental resistance and the enclosure rating for
the front of the PT is IP65F compliant.
IP International Protection

6 Dust and dirt will not enter interior.

(Enclosure protects against foreign objects.)

5 There are no adverse effects from a water stream

from any direction.
(Enclosure protects against water intrusion.)

F There are no harmful effects from oil droplets or

spray from any direction. (Enclosure protects
against oil intrusion.)

Note: May not be applicable in environments with long-term exposure to water or oil.

The PTs conform to UL standards (cULus) and EC
Directives.
In addition, there are no export restrictions on the PTs.
cULus certification is scheduled for the near future for
the NSH5 5-inch Hand-held PT.

Meets International Standards and
Exports are Not Restricted

RS-232C cable (loose wires)
Cable length: 3 m

RS-232C cable (loose wires)
Cable length: 10 m

Note 1: Use an OMRON USB Host Cable to connect an NS-series PT to a printer.
2: Site licenses are also available for users that need to use the CX-One on many computers.
Ask your OMRON representative for details.

CE,
CU
(approval
pending)

Advertising