The ns series is more beautiful and user-friendly, Powerful networking, More user-friendly – Omron NS8-V2 User Manual

Page 7: More beautiful, More strength in applications, System configurations

Advertising
background image

13

12

System Configurations

Ethernet

Various connections, such as 1:1, 1:2, 1:N, and M:N, are supported with Ethernet or serial connections.

NS-AL002 Converter
(Converts between
RS-232C and RS-422A.)

Host Registration Function

It is possible to register two or more PLCs as hosts and communicate with the PLCs by specifying the host ID and address when connected via Ethernet or
Controller Link.

PT:PLC = 1:1

PT:PLC = 1:N

PT:PLC = M:N

PT:PLC = 1:2

PLC

PLC

PLC

RS-232C

RS-232C

RS-232C

RS-232C

(1:1 NT Link, 1:N NT Link,
or Host Link)

NS-series PT

NS-series PT

NS-series PT

NS-series PT

NS-series PT

NS-series PT

CS/CJ-series PLC

CS/CJ-series
PLC

CS/CJ-series PLC

C200HX/HG/HE PLC

Ethernet Unit

(1:N NT Link)

Communications without

programming

Communications without

programming

Communications without

programming

Communications without

programming

More user-friendly

You can partially replace text and pictures from
your computer.

FTP (File Transfer Protocol) has been
added! Texts, lists, and recipes can be
replaced with the put/get command from
your computer! You can even replace
BMP files from your computer easily.

Screens, bitmaps, text, recipe data

The NS Series is more beautiful and user-friendly.

More beautiful

You can make beautiful screens with simple operations.

32,768-color display
The color variation displays
pictures brilliantly!

Windows fonts can be used for
switches and lamps

Ver.5

Beautiful BMP Parts Collection has
been newly added. Simply select
the desired part, paste it on your
screen, and make your screens
neat!

Auto font resizing function

Ver.5

Automatically resizes fonts to the
object size.No need to adjust font
sizes manually anymore!
Furthermore, just-fit font size
adjustments have been possible
since version 6.

PLC

Host Link CS/CJ-series,
CVM1/CV-series,
or C-series PLC

More strength in applications

Unit

Series and Models

A Memory Link has been added
to the communications method.
It allows the NS to communicate
with a Board PC.

The NS can be directly
connected to the OMRON

Temperature Controllers listed
on the right.

The following models, which have an RS-485 communications port and
support CompoWay/F communications, can be connected to the NS.

Temperature Controllers

E5AN- TC

E5AN- P

E5EN- TC

E5EN- P

E5AN- T

E5AN- L

E5EN- T

E5EN- L

E5CN- TC

E5CN- P

E5CN- T

E5CN- L

E5GN- TC

E5GN- P

Unit

Series and Models

E5ZN-SCT24S
(Terminal Unit)

E5AR- 03 -FLK

E5ER- 03 -FLK

E5ZN

Modular Temperature Controllers

Digital Controllers

E5AR

E5ER

Memory link

OMRON Temperature
Control Unit

CompoWay/F

The NS can be connected to a Board PC. The NS can also be directly
connected to an OMRON Temperature Controller.

E5AN/EN
Series

E5CN
Series

E5GN
Series

Thermocouple input

Temperature-resistance input

Thermocouple input

Temperature-resistance input

Temperature input

Analog input

Temperature input

Analog input

Thermocouple input

Temperature-resistance input

Temperature input

Analog input

Thermocouple input

Temperature-resistance input

Powerful Networking

NS-series PT

NS-series PT

CS/CJ-series PLC

CS/CJ-series PLC

NT Link

NT Link

Serial

Serial

Peripheral

bus

(Tool bus)

Serial

Peripheral
(or RS-232C)

PLC series

CJ Series

CS Series

030201

030201

CPU model

Lot number

CJ1H-CPU65H

CJ1H-CPU66H

CJ1G-CPU42H

CJ1G-CPU43H

CJ1G-CPU44H

CJ1G-CPU45H

CJ1M-CPU11

CJ1M-CPU12

CJ1M-CPU13

CJ1M-CPU21

CJ1M-CPU22

CJ1M-CPU23

CS1H-CPU63H

CS1H-CPU64H

CS1H-CPU65H

CS1H-CPU66H

CS1H-CPU67H

CS1G-CPU42H

CS1G-CPU43H

CS1G-CPU44H

CS1G-CPU45H

CS1D-CPU42S

CS1D-CPU44S

CS1D-CPU65S

CS1D-CPU67S

NS-series PT

RS-232C

Ethernet

Controller Link

CS/CJ-
series
PLC

NT Link

Serial

NS-series PT

Ladder program
(From CX-Programmer through NS-series PT to PLC)

Screen data or Data in Memory Card
(From CX-Designer through PLC to NS-series PT)

SPMA

Computer

Computer

*

To use the SPMA function through the PLC, the following

software and hardware versions are required.
NS-series PT: System version 3.0 or higher
NS Designer: Version 3.0 or higher or
CX-Designer: Version 1.0 or higher
CX-Programmer: Version 3.1 or higher
PLC: Lot No. 030201 and later (Refer to the following table.)

NS-series
PT

NS-series PT

NS-series
PT

CS/CJ-series
PLC

CS/CJ-series
PLC

CS/CJ-series PLC

Ethernet

NS-series
PT

Personal
computer

ControllerLink

CS/CJ-series

PLC

Direct access

Direct access

Direct access

Direct access

Direct access

Direct access

Exchanging Data with a PLC over a Network (Multihost)

Communicating with a PLC via NT Link,
using Ethernet without Special PLC Programming

Ethernet Communications without
Programming

NS-series PTs can communicate with a CS/CJ-
series PLC (equipped with an Ethernet Unit)
through “program-free” communications just
like NT Link communications. Data is transferred
through Ethernet through a simple PLC address
and initial communications setup.

Using Data Links between the PT and the PLC

Controller Link Interface Unit

The Controller Link is an FA network that can send and
receive large data packets flexibly and easily among
OMRON PLCs and IBM PC/AT or compatible computers. The
NS12 and NS10 PTs can be connected to the Controller Link
network easily via a Controller Link Interface Unit. When a
Controller Link network is used, data can be transferred
between multiple PLCs and NS12/NS10 PTs without writing
ladder programming to manage the communications.

SPMA (Single Port Multi Access) Function

Screen data can be transferred through the PLC from the CX-Designer to the PT connected to the PLC in series or via a network.

Ladder programs can be monitored or transferred from the CX-Programmer through the NS-series PT to PLCs connected to the PT
in series or via a network.

Screen transfer
from the
Controller Link
is supported
from version 6.

You may want to transfer screens to a PT through the PLC without changing
computer connections or to transfer a ladder program to the PLC through the PT
by using the Ethernet or Controller Link.

Advertising
This manual is related to the following products: