Flash synchronization and shutter speed, External fl ash unit, Information – Olympus E-PL3 User Manual

Page 105

Advertising
background image

105

EN

Information

11

Flash synchronization and shutter speed

Shooting

mode

Flash timing

Upper limit of

synchronization

timing

*1

Fixed timing

when fl ash

fi res

*2

P

1/ (lens focal length × 2) or synchronization
timing, whichever is slower

1/160

1/60

A

S

The set shutter speed

M

*1 Can be changed using menu: 1/60 – 1/160 [

# X-Sync.]: g “Customizing camera

settings” (P. 81)

*2 Can be changed using menu: 30 – 1/160 [

# Slow Limit]: g “Customizing camera

settings” (P. 81)

External fl ash unit

Optional fl ash units designed for use with this camera can be used for a variety of fl ash
effects. The external fl ashes communicate with the camera, allowing you to control the
camera’s fl ash modes with various available fl ash control modes, such as TTL-AUTO
and Super FP fl ash.
An external fl ash unit specifi ed for use with this camera can be mounted on the camera
by attaching it to the camera’s hot shoe. You can also attach the fl ash to the fl ash
bracket on the camera using the bracket cable (optional). Refer to the documentation
provided with the external fl ash units as well.

Functions available with external fl ash units

Optional fl ash

Flash control mode

GN (Guide number) (ISO100)

RC mode

FL-50R

TTL-AUTO, AUTO, MANUAL,
FP TTL AUTO, FP MANUAL

GN50 (85 mm*) GN28 (24 mm*)

D

FL-36R

GN36 (85 mm*) GN20 (24 mm*)

D

FL-300R

TTL-AUTO, MANUAL

GN20 (28 mm*)

D

FL-14

TTL-AUTO, AUTO, MANUAL

GN14 (28 mm*)

RF-11

TTL-AUTO, MANUAL

GN11

TF-22

GN22

* The focal length of the lens that can be used (Calculated based on 35 mm fi lm camera).

Advertising