3.3 CJC Output

The OME-DB-889D provides Cold-Junction Compensation (CJC) for the

thermocouple applications. If the CJC is required, place the JP17 in the position of the
channel to be used as a CJC reference. If the CJC is not required, Place the JP17 in
the position “X”.
CJC has output on connector CN7. Using a voltage meter measures CN7 which exists
a voltage related to the OME-DB-889D board temperature. The CJC voltage transfers
to temperature with formula:

T(

°C) = V*1000/24.4

-

+

CN7

CJC output

Voltage meter

A.GND

V: Voltage of CN7
T: Temperature of OME-DB-889D

Example: (Turbo C)
Multi-Function Card: OME-A-822PGL
The OME-DB-889D JP17 placed on “7”.

/*====================Example Program ===================*/
#include <stdio.h>
#include “A822.h>

main(void)
{int ad_channel , gain , trigger_mode, poll_data ;
float temp;
A822_Initialize(0,0x220, -1, -1);

/* Initials OME-A-822PGL Ref. OME-A-822PGH/L Software
Manual */

ad_channel=7;

gain=0;
trigger_mode=1;

for(;;)

{

A822_AD_SetChGainMode(ad_channel , gain , trigger_mode );

/* SettingOME-A-822 A/D channel =7 , Gain=1 , Trigger mode = Software

trigger */
poll_data=A822_AD_PollingVar();
temp=(float)(((poll_data-2048)*5/2048)*1000/24.4);

prinf(“ Temperature = %4.1f

°C \n”, temp);

}

}

OME-DB-889D User’s Manual