6. Calibration

The OME-DB-889D is calibrated to its best of operation. For environment subjected
to large vibrations, recalibration is recommended. Before calibrating the
OME-DB-889D, user should consider having the following available:

z

One 6 digital voltage meter

z

One temperature meter

z

One OME-A-82x series multifunction card

6.1 Calibration VR Description

There are two VRs on the OME-DB-889D.
VR Num.

Description

VR1

Amplifier Offset adjustment

VR2

CJC Gain adjustment

6.2 Calibration Steps

1.

Turn off computer power.

2.

Connect OME-A-822PGL (Or any OME-A-82x series multi-function card) to
OME-DB-889D.

3.

Setup OME-DB-889D to default setting

4.

Short CH0HI to CH0LO to A.GND of DB889D.

5.

Connect probe of voltage meter to CN7 (CJC output: + , A.GND : - ).

6.

Turn on computer power

7.

Wait about 5 minute (warn up).

8.

Run Calibration program of OME-DB-889D.

9.

Close the probe of temperature meter to OME-DB-889D them reading
temperature value.

10.

Adjust VR1 until the screen value = 0;

11.

Adjust VR2 until voltage meter reading value = temperature value X 2.44mV