Caution, Interrupt inputs, Encoder input specifications – Omron E7 User Manual

Page 5

Advertising
background image

G7/F7/L7/E7 inverter PLC

369

The minimum pulse widths for inputs IN00000 (A-phase input) and IN00001 (B-phase input) are as follows:

The minimum pulse width for input IN00002 (Z-phase input) is as follows:

Interrupt inputs

3G3RV-P10ST is equipped with inputs that can be used as interrupt inputs (interrupt input mode or counter mode) and quick-response inputs.
The minimum pulse width for these inputs is 50 µs.
Inputs IN 00003 and IN 00004 can be used as interrupt inputs.

Output specifications

Transistor outputs (sourcing/PNP)

Note:

When using OUT 01000 or OUT 01001 as a pulse output, con-
nect a dummy resistor as required to bring the load current
between 0.01 and 0.1 A. If the load current is below 0.1 A, the
ON-to-OFF response time will be longer and high-speed pulses
(source-type transistor outputs) will not be output. If the load cur-
rent is above 0.1 A, the transistor will generate more heat and
components may be damaged.

!Caution

Do not apply voltage in excess of the maximum switching capacity
to an output terminal. It may result in damage to the product or fire.

Encoder input specifications

Pulse plus direction input mode,

up/down inputmode, Increment mode

Differential phase mode

Item

Specification

Maximum switching capacity

4.5 to 30 VDC, 0.2 A/output

Minimum switching capacity

0.5 mA

Maximum inrush current

0.9 A for 10 ms

Leakage current

0.1 mA

Residual voltage

1.5 V max.

ON response time

20 µs max.

OFF response time

40 µs max. for 4.5 to 26.4 VDC, 10 to 100 mA
0.1 ms max for 4.5 to 30 VDC, 10 to 200 mA

Fuse

One fuse per output (cannot be replaced by user)

Circuit configuration

50 µs min.

ON

OFF

12.5 µs
min.

12.5 µs
min.

90%
50%
10%

90%
50%
10%

90%
50%
10%

T

1

T

2

T

3

T

4

100 µs min.

ON

OFF

ON

OFF

Phase A

Phase B

T

1

T

2

T

3

T

4

: 12.5 µs min.

50 µs min.

500 µs min.

ON

OFF

Phase Z

90%
50%
10%

Output LED

Internal
circuits

COM (+)

OUT

OUT

24 VDC

Signal level

All

EIA RS-422-A standards

Input impedance

A- and B-phase

280

Ω

Z-phase

260

Ω

Response frequency

A- and B-phase

50 kHz max.

Z-phase

1 kHz max.

Circuit configuration

A- and B-phase

Z-phase

410

Ω

Intrnal circuits

220 pF

330

Ω

330

Ω

A
B

/A
/B

560

Ω

Intrnal circuits

680 pF

180

Ω

180

Ω

Z

/Z

Y203-EN2-02-Katalog.book Seite 369 Mittwoch, 24. Mai 2006 2:22 14