Air conditioner opera tion, Product specifica tions – QUASAR HQ-2122UH User Manual

Page 6

Advertising
background image

5

AIR CONDITIONER OPERA

TION

6

PRODUCT SPECIFICA

TIONS

Model

HQ-2102UH

HQ-2122UH

COOLING CAPACITY

Btu/h

10,000

11,500

ELECTRICAL RATING

Phase

Single

+

Frequency

(Hz)

60

+

Voltage

(V)

115

+

Current

(Amps)

8.7

9.8

Input

(W)

980

1120

EER

(Btu/W.h)

10.2

+

MOISTURE REMOVAL

(Pints/h)

2.5

3.0

ROOM AIR CIRCULATION

(Cf/min)

320

330

DIMENSIONS

Height

cm (inches)

37.5 (14-

25

/

32

˝)

+

Width

cm (inches)

56 (22-

1

/

16

˝)

+

Depth

cm (inches)

60.6 (23-

27

/

32

˝)

+

NET WEIGHT

kg (lb)

35 (77)

+

GROSS WEIGHT

kg (lb)

39 (86)

+

NOISE LEVEL

Indoor (Hi/Lo)

dB (A)

50/46

51/47

Outdoor (Hi/Lo)

dB (A)

57/54

58/55

ECONOMY OPERATION

To reduce power consumption:

Press ECONOMY.
To cancel this operation, press once

more.

ECONOMY
Recommended for electricity cost saving. When economy button is
pressed, target temperature is shifted up 1°F, this will reduce operating
time of the compressor and therefore reduce power consumption. It
may, however, take a little longer for the compressor to cycle on and
thereby increase the room temperature slightly. Economy mode will
override your current set fan speed to “LOW”. However, the display will
still show the current set fan speed. Compressor stops when the room
temperature reaches the target temperature. It turns on again when
the room temperature rises. When power failure occurs, the economy
setting is canceled. Once power is resumed, reset the economy setting.

SETTING THE OFF TIMER

When the air conditioner in operation:
Press the TIMER button.
The SET/CANCEL indicator light will
blink awaiting for setting.
Press the TEMP/TIMER

or

button

until the preferred hour of operation is
reached.
Press the SET/CANCEL button to
complete the setting. At this time, the
SET/CANCEL indicator light is steady
instead of blinking.

NOTE
The hour reading will change back to the
set temperature reading after 10
seconds. (You can also revert to
temperature setting immediately by
pressing the TEMP/TIMER

or

buttons again.)

CHECK TIMER SETTING DURING OFF TIMER

Press the TIMER button to check the
remaining programmed timer setting.
The figure will be displayed for 10
seconds then will automatically switch
back to temperature setting.

NOTE
The timer figure will change according
to the time remaining (if you set it to turn
off 3 hours from now, the timer will show
“2” at an hour later).

CANCEL TIMER SETTING DURING OFF TIMER

Press the SET/CANCEL button to cancel
the timer setting. The SET/CANCEL
indicator light will turn off. However the
temperature remains displayed.

SETTING THE ON TIMER

When the air conditioner in operation:
Press the TIMER button. The TIMER
indicator light will blink to await for setting.
Press the TEMP/TIMER

or

button

until the desired hour for operation is
reached. Press the SET/CANCEL button
to complete the setting. At this time, the
TIMER indicator light is steady instead of
blinking.
The display will show the remaining hour
to the start of the operation (if you set to
turn on 3 hours from now, the timer will
show “2” at an hour later).
When set time is reached, the air
conditioner starts the operation under the
previous setting mode and the TIMER
indicator will light off. Now, the previous
set mode and the fan speed will light up.
Simultaneously, the display will show the
setting temperature.

CHECK TEMPERATURE/MODE/FAN SPEED
SETTING DURING ON TIMER

Press the TIMER button. The TIMER
indicator light will blink and the previous
temperature setting will be shown.
Simultaneously, MODE and FAN
SPEED indicator will light up. This
indication will last for 5 seconds, and
then the display will show the remaining
time. MODE and FAN SPEED indicator
light will turn off. At this time, the TIMER
indicator light is steady instead of
blinking.

CHANGE TEMPERATURE/MODE/FAN SPEED
SETTING DURING ON TIMER

Press the SET/CANCEL button to
cancel the timer setting.
Press the OPERATION. Set the desired
mode and the fan speed. Then press
OPERATION button to stop operation.
Start the TIMER setting again by
repeating the step from the “Setting the
on timer” procedures).

CANCEL TIMER SETTING DURING ON TIMER

Press the SET/CANCEL button to cancel the
timer setting. The SET/CANCEL indicator
light will turn off. To operate the air
conditioner before reaching the set timer:
• Press the SET/CANCEL to cancel the

timer.

• Press the OPERATION button to turn on

the unit.

ECONOMY

TIMER

TEMP/TIMER

SET

SET/

CANCEL

TIMER

SET

SET/

CANCEL

TIMER

TEMP/TIMER

SET

SET/

CANCEL

TIMER

TIMER

SET

SET/

CANCEL

OFF/ON

OPERATION

SET

SET/

CANCEL

OFF/ON

OPERATION

ECONOMY

TIMER

TEMP/TIMER

SET/

CANCEL

TIMER

SET/

CANCEL

SET/

CANCEL

OPERATION

SET/

CANCEL

OPERATION

TIMER

TIMER

TIMER

TEMP/TIMER

SET/

CANCEL

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

hr

°F

* Specifications are subject to change without notice for further improvement.