2 sg burner setup – Quincy Compressor Air Compressor User Manual
Page 15

3.2 SG Burner Setup
Boiler Model
SG-2
SG-3
SG-4
Burner Model
BF-3
BF-5
BF-5
Firing Rate
0.65
1.00
1.30
Insertion Depth
5.0"
5.0"
5.0"
Nozzle
.55 X 70
.85 X 60
1.10 X 80
Spray Pattern
solid
solid
solid
Pump Pressure
145 psi
145 psi
145 psi
Turbulator
0
0
2
Air Gate
4.5
4.0
5.6
BURNER MANUFACTURER Riello
BF3 and BF5
BURNER MANUFACTURER
Heat Wise
Pioneer
Boiler Model
SG-2
SG-3
SG-4
Burner Model
P-1 FV
P-1 KA
P-2 KA
Firing Rate
.65
1.00
1.30
Insertion Depth
3.5”
3.5”
3.5”
Nozzle
0.5 X 80
0.75 X 70
1.00 X 80
Spray Pattern
solid
solid
Semi Solid
Pump Pressure
200
200
200
Head Setting
6
3
3
Air Setting
12.0
11.5
11.5
12
Boiler Model
SG-2*
SG-3*
SG-4*
Burner Model
NEC - 1201
NEC - 1202
NEC - 1202
Firing Rate
0.65
1.00
1.30
Insertion Depth
3.5”
6.0”
6.0”
Nozzle
.50 X 60
o
.75 X 60
o
1.00 X 60
o
Spray Pattern
hollow
solid
solid
Pump Pressure
180 psi
180 psi
180 psi
Head Type
6 slot
9 slot
9 slot
Head Position
1.50
3.50
4.25
BURNER MANUFACTURER
Beckett
NX (NEC 1201, 1202)
* - These burners may not be used in Canada on Biasi equipment