7.6 Termination Resistors

Line termination resistors are provided for the input signals of each of the

DSCLP-200/300's RS-422/485 ports. Termination may be selected or removed
for individual signal lines using jumper blocks J6-J9.

RS-422 Rt = 100 ohm 1/2W

RS-485 Rt = 120 ohm 1/2W

+

-

RS-422/485 Receiver

Rt

RXD+ AUXIN+

RXD- AUXIN-

or

RS-485 termination

(120 omhs)

RS-422 termination

(100 ohms)

(factory default)

no termination

Jumpers J6-J9

1

3

4

2

1

3

4

2

1

3

4

2

Figure 21 --- RS-422/485 Line termination resistance values

DSCLP/SSCLP-200/300 User's Manual