Power amplifier management

Signal monitoring buses

1

(per CM16)

Number of Channels

4

Internal signal tap points

Pre-fader input signal

16

Post-fader input signal

16

Power amplifier output

16

Monitor input

Mixed with tap point signal at
unity gain

Nominal level

+4 dBu

Maximum level

+21 dBu

Input impedance

10 kOhm balanced

Configuration

Electronically balanced, shield
connected to chassis

Common-mode rejection

Typical, >50 dB, 20 Hz - 20 kHz
Worst case, >40 dB, 20 Hz-20kHz

Power amplifier interface

Compatibility

QSC Data Port equipped amplifiers

Connector and cable

HD-15 VGA cable, 2 meters length
qualified (for longer runs, contact
QSC’s Technical Services Department)

Amplifiers

16 amp channels grouped in pairs

Amplifier status monitor

Clip indicator

Senses channel clipping

Bridge mode status Sense bridge mode setting

Protect indicator

Senses amplifier protect status

Temperature meter

Reports amplifier operating
temperature

Over-Temp. Alert

Software adjustable threshold

AC power control

AC mode control

Switches amplifier between
normal and standby mode

AC power indicator

Indicates operate, standby, or
power-down mode

Control room foldback monitoring

Contact closure inputs and outputs

Output

Sum of Monitor input and
signal from internal monitor
tap point

Frequency response

25 Hz–20 kHz ±0.5 dB

Distortion

<0.05% THD @ +4 dBu out

Noise floor

-90.5 dB

Nominal level

+4 dBu

Maximum level

+21 dBu

Output impedance

75 Ohms balanced

Output load

600 Ohms minimum

Configuration

Active balanced

Level

Adjusts amplitude of signal from
tap point

Monitor in to monitor out

0 dB, ±0.5 dB

Control range

-95.5 to 0 dB in 0.5 dB steps

Inputs

1 discrete input (RLY/TRG IN)

Configuration

Single-ended input

Resistance for closure detect <1kOhm max
Resistance for open detect

>5 kOhm min

Input Voltage Limit

7.000 VDC maximum

“-” input terminal connected to chassis

Output

1 discrete output (RLY OUT)

Configuration

Electromechanical relay, dry
contacts, floating, C, NC, NO

Steady-state current (max.)

0.5 A

Switched current (max.)

0.25 A

Ground isolation

70 volts maximum

Connector

“Phoenix-style” (a.k.a.“Euro-style”)
detachable terminal block connectors