Table 13 and Table 14 list power supply specifications for the Heavy-Duty Bridge.

Note:

The standard package Bridge is powered by the included AC adapter. Table 13
and Table 14 do not apply to the standard package.

Table 13. Heavy-Duty Power Supply Specifications

Parameter

Min

Max

Normal Operating (J1455 – 12 V system)

9V

16V

Normal Operating (J1455 – 24 V system)

18V

32V

Cold Cranking (J1211)

4.5V

Jumper Start 5 minute (J1455 – 12 V system)

24V

Reverse Polarity (J1455 – 24 V system)

-24V

Max. Voltage

36V

Additional filtering is provided to accommodate the ISO 7637 Power Line Immunity and the SAE
J1113 Power Line Conducted Emissions requirements.

Table 14. Heavy-Duty DC Specifications

Symbol Parameter

Min

Typ

Max

Units

V

Supply

Supply Voltage

4.5

32

V

I

Supply

Supply Current @ V

Supply

= 12 V

200

350

mA

I

Inrush

Peak Inrush Current For 25 ms

2.9

A