2.4.2 Force High-Speed UART Clock (X2, X4, or X8, J10-J12)

These jumpers force an increase of the UART input clock frequency by a factor of

two, four, or eight. This feature can allow legacy software to use baud rates above
115,200 bits per second. It is also useful if the serial port device driver does not directly
support setting the higher baud rates through the Options Register (see page 10).

If one of these jumpers is applied, it overrides any value written to the Options

Register to set the clock multiplier by software. The effective baud rate will be either
two, four, or eight times the value for which the UART itself is programmed.

The factory default is none of these jumpers applied, which allows for software

control of the clock multiplier via the Options Register. The Options Register powerup
default is for a standard times-1 clock of 1.8432 MHz for compatibility with standard
serial ports.