Introduction, The lanmaster t8 hub w/sic slot, Lanmaster t8 – Transition Networks E-TBT-HB-0802 User Manual

Page 4: Port ethernet hub w/sic slot, Segment distance

Advertising
background image

LANMaster T8

18

1

8-Port Ethernet Hub w/SIC Slot

1. INTRODUCTION

This guide is intended for the system or network administrator
responsible for installing and monitoring a TRANSITION Networks
LANMaster T8 8-Port Ethernet Hub w/SIC Slot. A working
knowledge of local area network (LAN) operations, including
familiarity with communications protocols used on interconnected
LANs, is assumed.

The LANMaster T8 Hub w/SIC Slot

The LANMaster T8 8-Port Ethernet Hub w/SIC Slot (E-TBT-HB-
0802), is a stand-alone, fully functional Ethernet repeater.

LANMaster T8 8-Port Ethernet Hub w/SIC Slot Features

Media Dependent Interface (MDI) switch eliminates need
for RJ-45 crossover cable connection between LANMaster
T8 devices.

Comes with internal power supply.

Complies with Ethernet 802.3.

Slide-In Card (SIC) slots for optional installation of
additional media connections.

1

2

3

4

5

6

7

8

MDI/MDIX

T R A N S I T I O N

n e t w o r k s

Minneapolis, MN 55344 USA

LAN Master T8

8 Port Ethernet Hub w/SIC Slot

10BaseT Cable Specifications

The physical characteristics of the 10BaseT cable must meet or exceed
IEEE 802.3 10BaseT specifications.
Either shielded or unshielded twisted pair can be used. Level 3 wire or
better is recommended.

• Gauge. . . . . . . . . . . . . . . . . . 26 to 22 AWG
• Attenuation . . . . . . . . . . . . . Less than 11.5 dB @ 5-10 MHz
• Differential Characteristic . . 85 -110

Impedance

@ 10 MHz

• Maximum Distance . . . . . . . 100 Meters (330 Feet)

Segment Distance

Media

Maximum

Maximum

Minimum

Maximum

Segment

Number

Segment

Medium Medium

Type

MAU/

Length

Propagation

End to End

Segment

(meters)

Velocity

Propagation
Delay/Segment

10Base5

100

500

0.77 c

2570

10Base2

30

185

0.65 c

950

AUI

††

1

DTE/MAU

50

0.65 c

257

10BaseT

2

100

†††

0.59 c

1000

FOIRL

2

1000

††††

0.66 c

5000

FL

2

2000

0.66 c

5000

c = 3 x 10

8

meters/second

††

AUI connection is not a segment

†††

Maximum segment length depends on the cable characteristics

††††

A network of four repeaters and five segments, can have up to 3
coax segments and 2 required link segments. The maximum
length of a FOIRL link segment must not exceed 500 meters. If
your network has three repeaters and four segments, the
maximum length of a FOIRL link segment must not exceed 1000
meters.