Ensuring compliance with 5-segment rule, Powering the lanmaster t8 – Transition Networks E-TBT-HB-0802 User Manual

Page 8

Advertising
background image

LANMaster T8

14

5

8-Port Ethernet Hub w/SIC Slot

Ensuring Compliance with 5-Segment Rule

To conform to the Ethernet 802.3 specification, when connecting
LANMaster T8 Hubs, the transmission path between any two Data
Terminating Equipment (DTE) devices can consist of no more than
five segments. NOTE: A segment is the cable connection between
cable interfaces in an Ethernet LAN.

To assign segment numbers to cable connections:

1. Determine the two terminals in the network which are

separated by the greatest number of segments.

2. Assign a segment path between the terminals by labeling the

cable connected to one of the terminals “segment 1” and the
segment connected to the other terminal “segment n” (n =
total number of segments and must be 5 or fewer).

3. To verify that no segment paths contain more than n

segments, assign segment paths and numbers to all other
terminals.

. . . .
. . . .

. . . .
. . . .

. . . .
. . . .

. . . .
. . . .

SIC Connection

. . . .
. . . .

. . . .
. . . .

. . . .
. . . .

. . . .
. . . .

3

4

5

4

4

5

1

2

2

3

3

Powering the LANMaster T8

To power ON the LANMaster T8:

1. At LANMaster T8 back, locate the power receptacle and

associated fuse.

NOTE: Fuse must be installed at correct setting for power source voltage
before connecting to AC outlet.

2. Verify that fuse is installed at correct setting for power source

voltage.

NOTE: The installed fuse rating is indicated by the reading at lower right
corner of fuse holder.

If not installed at correct setting for power source voltage:

Carefully open fuse receptacle, using a small flat blade
screwdriver.

Rotate fuse holder 180° to the correct rating orientation.

Install fuse holder in correct rating orientation.

Close fuse receptacle.

3. Plug unit end (female) of power cord into LANMaster T8 power

receptacle.

4. Plug outlet end (male) of power cord into correct voltage AC

wall socket.

5. At LANMaster T8 front, verify that POWER LED is illuminated.

110-120

110-120

220-240

220-240

110-120 Orientation

220-240 Orientation

Fuse Holder

Fuse Holder