2008 all rights reserved – Toshiba LF610 User Manual

Page 2

Advertising
background image

Size

(mm)

Flow rate

0.3m/s

1m/s

3m/s

10m/s

2.5

0.005301

0.01767

0.05304

0.1767

4

0.01357

0.04524

0.13572

0.4524

6

0.03053

0.1018

0.3054

1.018

15

0.1908

0.6361

1.908

6.361

25

0.5301

1.767

5.301

17.67

32

0.8686

2.895

8.686

28.95

40

1.357

4.523

13.57

45.23

50

2.120

7.067

21.20

70.67

65

3.583

11.95

35.83

119.5

80

5.428

18.09

54.28

180.9

100

8.482

28.27

84.82

282.7

125

13.25

44.17

132.5

441.7

150

19.08

63.61

190.8

636.1

200

33.93

113.1

229.3

1,131

250

53.01

176.7

530.1

1,767

300

76.34

254.5

763.4

2,545

350

103.9

346.4

1,039

3,464

400

135.7

452.3

1,357

4,523

450

171.7

572.5

1,717

5,725

500

212.1

706.9

2,121

7,069

600

305.4

1,018

3,054

10,180

700

415.6

1,385

4,156

13,850

750

477.1

1,590

4,771

15,900

800

542.9

1,810

5,429

18,100

900

687.1

2,290

6,871

22,900

Factory default standard value table

Code

Item

Default value

Changed value

English unit

SI unit

A3

Exicitation Frequency

Value

Value

A4

Flow Direction

NORMAL

NORMAL

B1

Display 1

gal/min

m

3

/h

B2

Display 2

COUNT B

m

3

Display digit setting

(For Display 1 and Display 2)

1/1000

1/1000

B3

Custom Coefficient

0

0

B4

Custom Unit

Blank space in all field Blank space in all field

C1

Range Type

SINGLE

SINGLE

C2

Range 1

Value

Value

C6

Hysteresis

3.0%

3.0%

D1

Damping Constant

5 sec

1 sec

D2

Rate-of-change Limit

0.0%

0.0%

D3

Control Limit Time

0.0s

0.0s

E1

Low Cutoff

1.0%

1.0%

E2

Display Low Cutoff

LINEAR

LINEAR

F2

Manual Zero

0.0%

0.0%

G1

4-20mADC Alarm Output

4mA

4mA

G2

Output Low Limit

4mA

4mA

H1

DO1 Function

PLS OUT

PLS OUT

H2

DO2 Function (*)

EMPTY ALM

NO USE

H3

DO1 Active Status

NormOPEN

NormOPEN

H4

DO2 Active Status (*)

NormOPEN

NormOPEN

I1

Digital input (*)

C RS/ST

C RS/ST

I2

DI Detective Level (*)

H LEVEL

H LEVEL

J1

Counting Rate

Value

Value

J2

Pulse width setting mode

AUTO

AUTO

J3

Preset width

5ms

100ms

K1

Preset count

00000000

00000000

K2

Preset Function

HOLD

HOLD

L1,L2 High Alarm Set / Value

OFF 0.0%

OFF 0.0%

L3,L4 Low Alarm Set / Value

OFF 0.0%

OFF 0.0%

M1,M2 High High Alarm Set / Value

OFF 0.0%

OFF 0.0%

M3,M4 Low Low Alarm Set / Value

OFF 0.0%

OFF 0.0%

N1

Empty Pipe Alarm

NORMAL

NORMAL

N2

Self-disgnosis function

ON

ON

N3

Alarm Output Preset

CONV ONLY

CONV ONLY

P1

Password

000

000

P2

LCD display adjustment

3

3

P3

Switch position setting

BOTTOM

BOTTOM

* These functions are option.

Meter Size

Ex.Freq

(Hz)

Range 1

Counting Rate

inch mm

gal/min

ft/s

m

3

/h

m/s

1/10''

3

24

0.5 21.084

0.05

2.829 1 gal

1L

1/6''

4

24

1.5 24.707

0.1

2.211 1 gal

1L

1/4''

6

24

4 29.283

0.2

1.965 1 gal

1L

1/2''

15

24

25 29.283

2

3.144 1 gal

0.01m

3

1''

25

24

75 31.625

6

3.395 1 gal

0.01m

3

1 1/4''

32

24

125 32.171

10

3.454 1 gal

0.01m

3

1 1/2''

40

24

175 28.826

15

3.316 1 gal

0.01m

3

2''

50

24

300 31.625

25

3.537 10 gal

0.1m

3

2 1/2''

65

24

475 29.629

40

3.348 10 gal

0.1m

3

3''

80

24

650 26.766

60

3.316 10 gal

0.1m

3

4''

100

24

1,000 26.354

100

3.537 10 gal

0.1m

3

5''

125

24

1,750 31.625

150

3.395 10 gal

0.1m

3

6''

150

24

2,500 29.283

200

3.144 100 gal

1m

3

8''

200

24

4,500 29.649

300

2.653 100 gal

1m

3

10''

250

12

7,000 29.517

600

3.395 100 gal

1m

3

12''

300

12

10,000 28.283

900

3.537 100 gal

1m

3

14''

350

12

12,000 25.817

1,200

3.465 100 gal

1m

3

16''

400

12

16,000 26.354

1,600

3.537 100 gal

1m

3

18''

450

12

20,000 26.029

2,500

4.366 100 gal

1m

3

20''

500

6

25,000 26.354

3,000

4.244 100 gal

1m

3

24''

600

6

40,000 29.283

4,000

3.930 100 gal

1m

3

28''

700

6

50,000 26.892

5,000

3.609 100 gal

1m

3

30''

750

6

60,000 28.112

6,000

3.773 100 gal

1m

3

32''

800

6

70,000 28.825

7,000

3.868 100 gal

1m

3

36''

900

6

80,000 26.029

8,000

3.930 100 gal

1m

3

ERROR/ALARM

Error/Alarm type

Indicating message

Error contents

Self-diagnosis error

ROM ERROR

ROM error

RAM ERROR

RAM error

PARAMETER FAILURE

System parameter error

EXC CUR OPEN

Excitation circuit error

EXC CUR ERROR

Excitation current error

ADC ERROR

ADC error

INVALID TOTAL

Invaid totalizer counts

Settig error

HIGH OVER SPEC

Setting value exceeds the allowable high limit.

LOW OVER SPEC

Setting value exceeds the allowable low limit.

HIGH OVER CNT RATE

Counting rate exceeds the allowable high limit.

LOW OVER CNT RATE

Counting rate exceeds the allowable low limit.

MULTI RNG ERROR

Span is not appropriate for multi-range configuration.

Limit alarms

HIGH ALARM

Flow rate reading exceeds the high limit.

HIGH HIGH ALARM

Flow rate reading exceeds the high high limit.

LOW ALARM

Flow rate reading goes below the low limit.

LOW LOW ALARM

Flow rate reading goes below the low low limit.

OVER 125%

Measurement value exceeds the 125%

UNDER -125%

Measurement value goes below the 125%

Empty pipe alarm

EMPTY ALARM

Detector pipe is not filled with fluid.

LCD

Meter Size vs. Velocity/Rate

Size

(inch)

Flow rate

0.98ft/s

3ft/s

10ft/s

32.8ft/s

1/10''

0.02334

0.07115

0.2372

0.7781

1/6''

0.05975

0.1821

0.6071

1.992

1/4''

0.1344

0.4098

1.366

4.482

1/2''

0.8403

2.561

8.532

28.01

1''

2.334

7.115

23.72

77.81

1 1/4''

3.824

11.66

38.86

127.5

1 1/2''

5.975

18.21

60.71

199.2

2''

9.337

28.46

94.86

311.2

2 1/2''

15.78

48.09

160.3

526.0

3''

23.90

72.85

242.8

796.7

4''

37.35

113.8

379.4

1,245

5''

58.35

177.9

592.9

1,945

6''

84.03

256.1

853.8

2,801

8''

149.4

455.3

1,518

4,980

10''

233.4

711.5

2,372

7,781

12''

336.1

1,025

3,415

11,200

14''

457.5

1,394

4,648

15,250

16''

597.5

1,821

6,071

19,920

18''

756.3

2,305

7,684

25,210

20''

933.7

2,846

9,486

31,120

24''

1,344

4,098

13,660

44,820

28''

1,830

5,578

18,590

61,000

30''

2,101

6,403

21,340

70,020

32''

2,390

7,285

24,280

79,670

36''

3,025

9,221

30,740

100,800

unit : gal/min

unit : m

3

/h

2008

All Rights Reserved.

LCD display

Control switch

ETBK15031

2008-6(TDOC)