4-8 28.5 VDC GROUND POWER (WITH 208/240 VAC POWER) SYSTEM LOW POWER

DEMAND (100 amps or less).

1. TRANSPORT UNIT - The Turbo Start 4100 is easily transported us-

ing the wheels that are incorporated into the unit. The unit is en-

gineered to be pushed rather than pulled.

2. CONNECT AC POWER CORD TO UNIT - Make sure that the On/Off switch

is in the Off position. Ensure 208-240 Single Phase VAC 30AMP power

cord is properly connected to an approved AC power supply. Unit shall

be in Horizontal position to ensure unit’s vent ports are free from

blockage. After approximately 5-8 seconds, unit’s LED status indica-

tor will illuminate indicating power cells state of charge. Cooling

fan will operate. Ensure LED status indicator and cooling fan are

operational prior to continuing to step 3.

NOTE

THE ON/OFF SWITCH CONTROLS THE AC POWER INPUT. IT DOES NOT CONTROL

THE DC POWER OUTPUT. IF YOU PLUG THE UNIT INTO AN AIRCRAFT WITH THE

AC ON/OFF SWITCH IN THE OFF POSITION, THE UNIT WILL STILL PROVIDE

24VDC POWER TO THE AIRCRAFT.

3. CONNECT DC POWER CABLE TO UNIT - Ensure power cable connector is

fully seated into unit’s receptacle.

4. CONNECT DC POWER CABLE TO AIRCRAFT - Connect to aircraft ground

power receptacle. DC bus power should come on and aircraft volt

meter should indicate 27.5 VDC to 23.5 VDC (23 VDC minimum).

5. MOVE THE ON/OFF SWITCH TO THE ON POSITION - After approximately

2-3 seconds, the unit’s LED bar status indicator will illuminate,

indicating the power cells state of charge. The cooling fans will

operate. Ensure the LED status indicator and cooling fans are opera-

tional. At this time the unit can provide 100 amps at 28.5 VDC. If

the current demand is above 100 amps, the output voltage will de-

crease and two or more LED status indicator bars will illuminate.

7. REMOVING DC POWER SUPPLY FROM AIRCRAFT

a. Switch the ON/OFF switch to the OFF position

b. Remove DC power cable GPU connector from aircraft.

c. Remove DC power cable connector from Turbo Start (if neces-

sary).

4-9 POWER CELL RECHARGE

1. CONNECT AC POWER CORD TO UNIT -

Unit shall be in horizontal po-

sition to ensure unit’s vent ports are free from blockage

. - Ensure

208-240 VAC power cord is properly connected to an approved AC power

supply. After approximately 5-8 seconds, ensure unit’s LED status

indicator illuminates indicating power cell state of charge and cool-

ing fan is operating.