Sm 40 g s up er m ara th on g as fr ye r, Dean – Teac SM40G User Manual

Page 2

Advertising
background image

Dean

®

SM

40

G

S

up

er

M

ara

th

on

G

as

Fr

ye

r

M

o

d

el

#_

__

__

__

__

__

__

__

C

SI

Se

ct

io

n

1

14

00

5489 Campus Drive

Shreveport, LA 71129 USA

Tel: 318-865-1711

Tel: 1-800-221-4583

Fax: 318-868-5987

E-mail: [email protected]

http://dean.enodis.com

Bulletin No. 830-0059 1/08

Litho in U.S.A. ©Frymaster, LLC

MIn./MAx. oIl

CAPACIty

overAll SIze (cm)

DrAIn

vAlve

(cm)

DrAIn

vAlve

heIght

(cm)

no.

of

tubeS

fryIng

AreA

(cm)

wIDth

DePth

overAll

heIght

work

heIght

ClASS

ShIPPIng

lbs./cu.ft.

(kg/m

3

)

35-43 lbs.

(17-21 L)

15.50”

(39)

29.25”

(74)

45”

(114)

35”

(89)

1.25”

(3.175)

17.5”

(44)

3

14 x 14”

(35 x 36)

85

180 lbs./15

(82/0,42)

diMenSiOnS

pOwer requireMentS

ShOrt terM SpeciFicAtiOn

Shall be DEAN free-standing cool zone deep fat fryer, Model
SM40G. Only 15.50” (39 cm) wide, 35-43# (17-21 L) oil capacity,
requiring 105,000 BTU (26,481kcal) (30.8 kW) natural or LP gas
input (3/4” N.P.T. connection) and mechanical controls.

OrderinG dAtA

Please specify:
Natural or propane gas
Altitude -- if above 1,999 ft. (609 m)

nOte:

DO NOT CURB MOUNT.

SIDE VIEW

FRONT VIEW

TOP VIEW

7.20

(18)

(74)

29.25

CONNECTION

w/ 3/4" NPT PIPE

2.60

(6)

GAS LINE

35.00

(89)

15.50

(39)

INCHES

(19)

7.62

(5)

2.00

(114)

45.00

(cm)

We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.

nAturAl or lP gAS

InPut rAtIng

gAS

ConneCtIon

eleCtrICAl

reQuIreMent

105,000 BTU/hr.

(26,481 kCal/hr.) (30.8 kW)

3/4” N.P.T.

regulator not required

NONE

Advertising