Installation Procedure

CAUTION: When assembling the Drip Zone Valve

Kit components, use just 1

1

2

to 2 turns of Teflon

tape on male threads. Never use pipe dope.
To achieve a leak-free thread connection, turn the
male fitting until it is finger tight, then add one or
two more turns. Over-tightening can cause splitting
and failure of the female threads.

Important: Ensure the Y-Filter, Jar Top Valve and

Pressure Regulator are installed in the correct flow
orientation. Flow direction arrows are provided on each
component. Refer to Figure 1 and Figure 2.

1. Using the Close Nipple, install the Ball Valve to the Jar

Top Valve inlet.

2. Remove the Bonnet Ring from the Y-Filter by turning

it counterclockwise. Remove the Bonnet and Filter
Screen. See Figure 1.

3. Install the Y-Filter inlet to the Jar Top Valve outlet.

4. Install the Pressure Regulator inlet to the Y-Filter outlet.

5. Reassemble the Y-Filter components.

Note: Hand tighten the Bonnet Ring only – do not
over-tighten.

Important: Refer to the provided Toro Jar Top Valve,

Anti-Siphon (AVB) installation instructions for additional
important installation and operating information.

6. To determine the recommended minimum/maximum

number of drip emitters per Jar Top valve, refer to the
table below.

For technical assistance, call 1-800-367-8676.

Kit Components

• 3/4" (FPT X FPT) Ball Valve

• 3/4" (MPT X MPT) F Series Y-Filter, 150 Mesh

• 3/4" (FPT X FPT) Toro Jar Top Valve, Anti-Siphon (AVB)

• 3/4" NPT Close Nipple

• 3/4" (FPT X FPT) Pressure Regulator, 25 PSI at 0.25–8 GPM

Drip Zone Valve Kit
Model 53749
Installation Instructions

Specifications

• Inlet/Outlet Pipe Connection: 3/4" Female NPT

• Maximum Supply Pressure: 150 PSI

• Downstream Pressure Regulation: 25 PSI

• Flow Rate @ 25 PSI: 0.25–8 GPM

• Filtration: 150 Count Stainless Mesh Screen

• Irrigation Control Valve:

• Automatic, Anti-Siphon, Toro Jar Top Model

• Manual Bleed and Flow Control

• 24 V a.c., 60 Hz Solenoid

Bonnet Ring

Bonnet

Filter Screen

Jar Top Valve

Y-Filter

Ball Valve

From Water
Supply

To Emitters

Pressure

Regulator

Close Nipple

Body

Note: Valve must be
installed at least 6"
above the highest
emitter it controls.

Figure 2

Figure 1

© 2005 The Toro Company, Consumer Division • An ISO 9000-certified Company

Form Number 373-0347 Rev. B

P.O. Box 489, Riverside CA, 92502 • www.toro.com

RELEASED Version ©Toro 2005-2005

Advertising