Symptom

Probable

Cause

Corrective Action

Recommended Tools

SPEED

FLUCTUATION

E2: CAL


Speed Fluctuation
(Due to high friction)







Speed Fluctuation
(Due to Voltage
fluctuation)






Bad Data Feedback









Incorrect Speed
Sensor Gap


• Perform Push Off Test (page 24)

• Perform Amp Draw Test (page 20)



--------



• Check Line voltage for fluctuations.

• Have customer take corrective action.



--------



• Verify tach feedback accuracy through

out the speed range.

• If inaccurate perform speed sensor test

(page 21)



--------


• Verify correct Speed sensor Gap.

• Gap should be equal to the thickness of

(3) credit cards pressed together
(approximately 1/8 to ¼ inch)



------

















Multi-meter

Socket Set

Silicone Lubrication
Packet

Silicone Lubrication
Applicator



Note: All

trouble shooting
should be
performed in
Calibration
Mode:
See SG-12








Support Services 800-883-8783

Mon-Fri 8:30am-5:00pm Central Time Zone