True Fitness 350-750 User Manual

Page 14

Advertising
background image




















































Symptom

Probable

Cause

Corrective Action

Recommended Tools

NO DISPLAY

No power at the 110
VAC outlet.












No power to the
treadmill.



















No power to the
control panel.

• Check home circuit breaker. Reset as

necessary.

• Test for 110 VAC at outlet.

• Identify if outlet is a GFI.

Note: Some brands of GFI

outlets are too sensitive for

treadmill use. Call the help

line if encountering GFI

issues.

--------

• Check for AC light on PWM.

(See diagram pages 23-30)

• Check for 110 VAC at power cord.

Replace if no power.

• If Yes- Check for 110 VAC at tread

power switch. Replace if no power.


• If Yes-Check for 110 VAC at tread

circuit breaker. Replace/ reset if
necessary.

• If Yes- Check for 110 VAC at PWM

across AC1 & AC2.

• If Yes- Replace PWM.

--------


• Check status LED +11 VDC on PWM

(See diagram pages 23-30). If not
remove fuses and check continuity as
replace as needed.


• If Yes- Check wire harness connections

at PWM and Control Panel. Reconnect
as needed.


• If Yes- Check voltage on harness at

panel. Refer to wiring diagram for your
machine type in wiring diagram section.
If voltage is present– replace panel and
recalibrate (page 16). If voltage is

not

present check voltage at PWM. If
voltage is present at PWM replace
pedestal wire harness.

If 0 VDC

replace PWM and recalibrate (page 16).

Allen Key set.

Phillips head
screwdriver.

Multi-meter.








Note:
All trouble
shooting should
be performed in
calibration
mode.
Page 16