background image

individually and allows more gentle gating compared to
the full-band mode. This is achieved by letting certain
frequency areas of the dry signal pass, even when the
gate is active.
Dry Blend is excellent for reducing/removing significant
noise without sounding un-natural. Noise Gate with Dry
Blend activated works great when the gate is used in
an amp’s effects loop or after hi-gain distortion pedals.

Note that “Min”, “Mid” and “Max” refers to Dry Blend
and therefore “Min” mode provides the most
attenuation, “Max” mode provides the least.

13 – A/B toggle
When the A/B switch is off (not lit), you can switch off
channels A and B as if you were using two separate
pedals. When the A/B switch is on (LED green), you
can toggle between channels A and B simply by
pressing the A or B switch. To completely bypass the
pedal, press the switch of the currently active channel.

Noise Gate – Suggested Settings

Gentle Noise Gate

Heavy Noise Gate

Dry Blend set to “max”

OPERATION & SUGGESTED SETTINGS

17

Noise Gate simple setup procedure:
•

Start out by setting all controls in 12 o’clock
position

•

Turn up the guitars volume pot without playing

•

Now tweak the THRESHOLD knob until you find
the exact point where the desired attenuation of the
noise is achieved

•

Experiment with the three Dry Blend modes