23 7. 3 synchro. scan operation, 2 ) setting by the frame – Toshiba IK-TF9U User Manual

Page 23

Advertising
background image

23

7. 3 Synchro. Scan Operation

The shutter speed can be set by the double horizontal scanning period (2H) or by the frame.

( 1 ) Setting by 2H

2H/1592H ~ 1590H/1592H stands for the setting by the 2H and the shutter speed can be set by the 2H (62.8

µ

s).

When operating Partial Scannig, the number’s listed below can be used for setting.

25fps, E25fps

2H/1270H ~ 1268H/1270H

30fps, E30fps

2H/1060H ~ 1058H/1060H

35fps, E35fps

2H/910H ~ 908H/910H

40fps, E40fps

2H/774H ~ 772H/774H

45fps, E45fps

2H/706H ~ 704H/706H

50fps, E50fps

2H/636H ~ 634H/636H

( 2 ) Setting by the frame

2FRM to 512FRM stand for the setting (long period exposure) by the frame.

The video signal stored during the frame period set is output as 1 frame video image at a frame interval
specified.

(4FRM setting)

n n+1

RGB data

(video interval image)

(Internal VD)

FVAL

LVAL,
DAVL

( 7 ) Setting to factory setting status

All the settings can be returned to the factory default status (preset status).

(1) If characters are displayed on the screen, press the [DISP] button to disable the character display.

(2) Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.

(3) The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed

for approx. 1 second.