Installation, Considerations before installing hood, Parts included – Thermador PROFESSIONAL PH PH54 User Manual

Page 5: Parts not included, Do not use flex ducting, Remote blowers require a five wire installation

Advertising
background image

English 3

Installation

Considerations Before
Installing Hood

Parts Included

Hood Canopy

Halogen bulbs, installed

Filters (2, 3, or 4 depending on model and size)

Metal Transition with backdraft damper installed

Fasteners

Remote Blower (“pigtail”) Adaptor

Wooden Strip used for Hood Mounting Bracket

Wire Nuts

2 - 175W PAR-38 Heat Lamps or
2 - 250W PAR-40 Heat Lamps (on some models)

Use & Care Manual / Installation Instructions

Registration Card

Parts NOT Included

Duct Tape

1/2" Conduit

Ventilator — The hood can be installed with blower
models VTN630C, VTN1030C, VTI610D, VTI1010D,
VTR630D, VTR1030D, or VTR1330E.

Optional duct cover, 6" DC(30,36, 48)US or
12" DCT(30, 36, 42, 48)US height (available for
purchase separately).

Optional Remote Control (available for purchase
separately with select models).

Optional Keep Hot Shelf, KHS(30, 36, 42, 48)QS
(available for purchase seperately with hood widths
30”, 36”, 42”, and 48”)

1. For the most efficient air flow exhaust, use a straight

run or as few elbows as possible.

2. Do not use flex ducting.
3. COLD WEATHER installations should have an

additional backdraft damper installed to minimize
backward cold air flow and a non-metallic thermal
break to minimize conduction of outside temperatures
as part of the ductwork. The damper should be on the
cold air side of the thermal break. The break should be
as close as possible to where the ducting enters the
heated portion of the house.

4. Hood installation height above a cooktop or range can

vary. To obtain the necessary installation height above
a Thermador Professional Cooktop or Range, consult
the appliance's installation manual.
* For indoor grill installations, Thermador

recommends a minimum of 36" clearance and
remote and inline blowers only (VTR630D,
VTR1030D, VTR1330E, VTI610D, or
VTI1010D).

5. Remote blowers require a five wire installation.
6. Make-Up Air: Local building codes may require the use

of make-up air systems when using ducted ventilation
systems greater than specified CFM of air movement.
The specified CFM varies from locale to locale. Consult
your HVAC professional for specific requirements in
your area.