Appliance Installation

CAUTION:

Vent unit to the outside of building only.

The hood can be mounted on a wall or suspended from a
cabinet. Both vertical and horizontal discharge are possible
with either mounting method.

Discharge Direction:

The hood is shipped ready for vertical discharge. To
change to horizontal discharge, move the discharge cover
shown in Figure 1 to the top of the hood. The plate is held
in place by four (4) screws.

Assembly of the Transition:

The supplied transition mounts to the top or rear of the
hood depending on the discharge direction.

1. Align mounting holes at base of transition with

mounting holes on 1/2” flange located at the top or rear
of the hood, depending on direction of discharge.

2. Fasten transition to hood using two (2) # 8 sheet metal

screws (included with hood).

3. Seal connection between transition and hood with duct

tape.

4. Remove tape holding damper closed.

See Figure 2 for overall hood dimensions.

* Varies by model.

Note:
Read Remote Control Installation Instructions before
continuing if using this accessory.

Figure 1: Discharge Direction

This opening
is covered for
horizontal
discharge

This opening
is covered
for vertical
discharge

Figure 2: Overall Dimensions

30", 36", 42", 48", 54"*

18"

24", 27"*