PARAMETER MEASUREMENT INFORMATION
ethernet timing of XMIT signals
NO.
PARAMETER
MIN
TYP
MAX
UNIT
350
JAMTIM
Time from COLL sampled high (TXC high) to first transmitted ”JAM” bit on TXD
(see Note 20)
4
cycles
351
COLSET
Setup of COLL high before TXC high
20
ns
352
COLPUL
Minimum pulse duration of COLL high for guaranteed sample
20 ns + 1 cycle
ns
NOTE 20: The JAM pattern is delayed until after the completion of the preamble pattern. The TMS380C26 transmits a JAM pattern of all ”1”s.
350
TXC
TXD
COLL
Data
Data
Data
JAM
JAM
JAM
351
352
Figure 27. Ethernet Timing of XMIT Signals