Select Venting System - Horizontal or Vertical
With the appliance secured in framing, de-
termine vent routing and identify the exterior 
termination location. The following sections 
describe vertical (roof) and horizontal (exterior 
wall) vent applications. Refer to the section 
relating to your installation. A list of approved 
venting components is shown on Pages 33 
through 35.
Installation of Vent Restrictor
A vent restrictor may be needed with this appliance, 
install vent restrictor (provided) in the appliance top 
fl ue outlet as shown in Figure 16 (SSDVT-3530 
and SSDVT-4035) or rear fl ue outlet as shown in 
Figure 17 (SSDVR-3530 and SSDVR-4035). It is 
held in place by friction, only.
Step 3. INSTALL THE VENT SYSTEM
General Information
These instructions should be used as a guide-
line and do not supersede local codes in any 
way. Install vent according to local codes, 
these instructions, the current National Fuel 
Gas Code (ANSI-Z223.1) in the USA or the 
current standards of CAN/CGA-B149.1 and 
-B149.2 in Canada. 
Use only approved venting components. See 
Approved Vent Components on Page 2.
These fi replaces must be vented directly 
to the outside.
The vent system may not service multiple 
appliances, and must never be connected to a 
fl ue serving a solid fuel burning appliance. The 
vent pipe is tested to be run inside an enclosing 
wall (such as a chase). There is no requirement 
for inspection openings in the enclosing wall at 
any of the joints in the vent pipe. 
WARNING
Failure to reinstall and securely 
tighten cover plate screws could 
result in leakage of fl ue products 
into the living space. Vent cover 
plate and vent seal plate must 
remain securely installed on 
unused vent collar. Failure to do 
so could result in leakage of fl ue 
products into living space.
Vent Restrictor Installation
(Top Vent)
A vent restrictor may be needed when verti-
cally terminating the vent system above the 
roof (when using the appliance top vent), 
install vent restrictor in the top vent of the 
fi replace outlet on SSDVT-3530/4035 series 
models. If needed, install the restrictor orien-
tated as shown, either from inside or outside 
the unit,in the inner fi replace collar.
Appliance Top
Vent Outlet
Restrictor
Inner
Fireplace
Collar
VENT RESTRICTOR INSTALLATION
(REAR VENT)
A vent restrictor may be needed when horzon-
tally terminating the vent system from the rear 
of the appliance (when using the appliance rear 
vent), install vent restrictor in the rear vent of 
the fi replace outlet on SSDVR-3530/4035 series 
models, in any installation that has a vertical 
vent run in excess of three feet (0.914 meters).
If needed, install the restrictor orientated as 
shown, either from inside or outside the unit, in 
the inner fi replace collar
Inner Fireplace
Collar
Appliance Rear 
Vent Outlet
Restrictor