Important le canada seulement – TOA Electronics SSDVT-4035CNM User Manual
Page 36
 
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
36
Note - Use extra care not to engage the 
orifi ce strip with the 7/16" open end wrench 
(contacting the orifi ce strip could cause strip 
distortion rendering the pilot inoperative). 
Also avoid wrench contact to any of the 
other pilot parts.
Use a 7/16" open end wrench and turn the 
pilot hex fi tting counter-clockwise 1/4 turn. 
(See Figure 63).
Note - The orifi ce strip tab may be randomly 
located on any side of the hex fi tting.
d. Push the orifi ce strip tab all the way 
against the hex fi tting to align the appropri-
ate gas type orifi ce (see Figures 62 & 63). 
The type of gas for which the pilot is set, 
is, the gas type shown on the tab.
e. Retighten, clockwise, the pilot hex 
fi tting until the pilot hood aligns with the 
thermocouple and thermopile as indicated 
by the arrows shown in Figure 63.
Adjusting Knob
Conversion screw
(blue natural gas;
red LP/propane gas)
Regulator Cap
Honeywell Millivolt Gas Valve
Figure 61
Pilot for Honeywell Millivolt Gas Valve
Figure 62
b. Attach manometer to the manifold side 
pressure test fi tting and verify manifold 
pressure reads 3.5 inches water column 
(0.87 kPa) for natural gas, and 10.0 
inches water column (2.49 kPa) for pro-
pane gas.
c. Convert the pilot orifi ce as follows (see 
Figures 62 & 63):
b. Attach manometer to the manifold side 
pressure test fi tting and verify manifold 
pressure reads 3.5 inches water column (0.87 
kPa) for natural gas, and 10.0 inches water 
column (2.49 kPa) for propane gas.
c. Refer to Figure 60 and remove the pilot 
hood assembly to access the hexed pilot orifi ce. 
Remove and replace the orifi ce with the one 
provided with the kit.
Step 5. Millivolt Appliances
Honeywell Systems -
a. Convert the gas valve as follows 
(see Figure 61): Remove the plastic protecting 
cap. Remove the gas type setting screw by 
turning it counterclockwise. Obtain the replace-
ment gas type setting screw from the kit and 
screw it into place (red for propane and blue 
for natural gas). Tighten the gas type setting 
screw by turning it clockwise. Replace the 
plastic protecting cap. 
Pilot for Honeywell Millivolt Gas Valve
(Loosening of Hex Fitting For
Orifi ce Strip Tab Positioning)
Figure 63
7/16 in. Open 
End Wrench
Hood
Hood
Alignment
Orifi ce 
Strip Tab
Take care not to contact the orifi ce strip tab 
with the hex fi tting wrench - distortion of the 
tab may render the pilot inoperative.
LP (propane) Gas Posi-
tion - 1/16 inch hole, 
LP and red color shown 
on tab. 
Natural Gas Position 
- NAT shown on tab. 
Top View of Hex Fiting and Orifi ce Strip Tab
Orifi ce Strip Tab Position Identifi cation
For LP (propane gas) and Natural Gas
P
L
NAT
SIT Millivolt Gas Valve
Pilot for SIT Millivolt
Gas Valve
Figure 60
Pressure
Regulator
Remove 
These 
Components
Figure 59
Pilot
Orifi ce
Gas conversion kits are available to adapt the 
appliance from the use of one type of gas to 
the use of another. These kits contain all the 
necessary components needed to complete the 
task including labeling that must be affi xed to 
ensure safe operation.
Kit part numbers are listed here and the following 
steps detail the conversion procedure. 
Step 1. Turn off the gas supply to the appliance. 
Remove the front glass door/frame from the 
appliance. Access the control compartment.
Step 2. Carefully remove the logs. Exercise care 
so as not to break the logs.
Step 3. Locate the screws securing the burner 
assembly to the appliance. Remove the burner 
assembly and retain the securing screws.
Step 4. Millivolt Appliances - SIT Systems
a. See Figure 59 and the instructions 
provided with the kit. Using a Torx T20, 
tool or or standard fl at screwdriverremove 
and discard the three pressure regulator 
mounting screws. Remove the pressure 
regulator, spring, poppet, diaphragm and 
bushing. Discard all removed components. 
Ensure the rubber gasket installed on the 
back of the replacement pressure regulator 
is properly positioned and install the new 
pressure regulator using the new screws 
supplied with the kit. Tighten screws to 25 
In. lb. torque.
IMPORTANT
LE CANADA SEULEMENT
La conversion devra être effectuée 
conformément aux recommanda-
tions des autorités provinciales 
ayant juridiction et conformément 
aux exigences du code d'installation 
CAN1-B149.1 ET.2.