Unit Installation

Indoor Unit

1. Select a location to route tubing,

wiring and drain pipe between
the indoor and outdoor units.

2. Make a hole in the wall using a

key hole saw or hole-cutting drill
attachment.

The hole should be made at a

slight downward slant to the
outdoor side (Figure 5).

Before cutting, check that no pipes

or studs are directly behind the
place to be cut. Avoid areas where
electrical wiring or conduits are
located.

3. Place the unit on a solid and level

foundation.

4. Tubing, wiring through and drain

pipe of low wall and floor
mounted units can be routed,
rear or right side of unit when
facing front.

Ceiling mounted can be routed

straight downward.

5. Pull air filters upward (Figure 6).

Figure 5

6. Unscrew at the return grille

(Figure 7).

7. Unscrew at the grille bottom

hinges, pull out the screw, and
unscrew at the side panel front
(Figure 8). Then, push down on
the side panel front and pull up
(Figure 9).

Note: = A 0.49" x 1.575" - 4 SLOT
(Mounting hole) (12.5 mm 40.0 mm)

Unit Size

B

MCX 512-518

36.2" (920)

MCX 524

46.1" (1,170)

MCX 530-536

55.9" (1,420)

MCX 042-048

65.7" (1,670)

MCX 060

75.6" (1,920)

8. Place or hang the unit at the

selected position.

9. Replace both right and left side

panels, and the return grille after
the installation of wiring, tubing
and piping is complete.

Outdoor Unit

See the proper installation method
provided in the Installation Manual
for the outdoor unit.

Indoor side

Figure 6

Pull

Pull

Figure 7

Figure 8

Figure 9

Outdoor side

Figure 10