Performance data, 30 ton) – Trane RT-PRC010-EN User Manual

Page 49

Advertising
background image

49

RT-PRC010-EN

Performance
Data

Note:
1. Important: Maximum static pressure leaving the rooftop is 4.0” H

2

O positive. The static pressure drops from the supply fan to the space cannot exceed 4.0” H

2

O.

Figure PD-3— Supply Fan Performance With VARIABLE FREQUENCY DRIVE or WITHOUT INLET VANES — 30 Ton

(30 Ton)

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

5.5

6.0

6.5

7.0

7.5

8.0

0

2000

4000

6000

8000

10000

12000

14000

16000

18000

20000

CFM

ST

A

T

IC

PR

ESSU

R

E

, I

n

ch

es w

.c

.

1400 RPM

800 RPM

900 RPM

1000 RPM

1100 RPM

1200 RPM

1300 RPM

600 RPM

700 RPM

500 RPM

S_HFC30
Dual 18 X 18 Fans
Entranc e Losses
- w ithout Inlet Guide V anes
- w ithout Ev ap Coil
- w ithout Filters
- w ithout Return A ir Dampers
- w ithout Ex haust
Fan Curv e Limits
- Minimum Motor HP = 5
- Maximum Motor HP = 20
- Maximum RPM = 1379
- Maximum CFM = 13,500
- Maximum Static Press ure
Leaving the Unit = 4.0" w .c.

5 HP

7.5 HP

10 HP

25 HP

15 HP

20 HP

3 HP

40%

w

o

c

fm

50%

60%

80%

90% w ocf m

70%

Advertising