Test Setup

5.2.2

Test Setup Diagram

Figure 2. TPS53125EVM-599 Recommended Test Setup

5.3

Start-Up/Shutdown Procedures

Perform the start-up and shutdown procedures in the following manner.

1. Increase V

IN

from 0 V to 12 Vdc.

2. Vary LOAD1 from 0 V – 4 Adc.
3. Vary LOAD2 from 0 V – 4 Adc.
4. Vary V

IN

from 8 Vdc to 22 Vdc.

5. Decrease V

IN

to 0 Vdc.

6. Decrease LOAD1 to 0 A.