4 output ripple voltage measurement procedure, 5 equipment shutdown, 6 tps53125evm-599 test data – Texas Instruments TPS53125EVM-599 User Manual

Page 8: 1 efficiency

Advertising
background image

0

1

2

3

4

5

I

- Load Current - A

LOAD

50

55

60

65

70

75

80

85

90

95

h

-Efficiency-%

V = 8 V

I

V = 12 V

I

V = 22 V

I

TPS53125EVM-599 Test Data

www.ti.com

7. Decrease LOAD2 to 0 A.

5.4

Output Ripple Voltage Measurement Procedure

Perform the Output Ripple Voltage Measurement procedure in the following manner.

1. Increase V

IN

from 0 V to 12 Vdc.

2. Adjust LOAD1 to desired load between 0 Adc and 4 Adc.
3. Adjust LOAD2 to desired load between 0 Adc and 4 Adc.
4. Adjust V

IN

to desired load between 8 Vdc and 22 Vdc.

5. Connect oscilloscope probe to CN1 or CN2 shown in

Figure 2

.

6. Measure Output Ripple.
7. Decrease V

IN

to 0 Vdc.

8. Decrease LOAD1 to 0 A.
9. Decrease LOAD2 to 0 A.

5.5

Equipment Shutdown

Shut down the equipment in the following manner.

1. Shut down oscilloscope.
2. Shut down V

IN

.

3. Shut down LOAD1.
4. Shut down LOAD2.
5. Shut down FAN.

6

TPS53125EVM-599 Test Data

Figure 3

through

Figure 10

present typical performance curves for the TPS53125EVM-599. Because

actual performance data can be affected by measurement techniques and environmental variables, these
curves are presented for reference and may differ from actual field measurements.

6.1

Efficiency

V

IN

= 8 V – 22 V, V

OUT1

= 1.05 V, I

OUT1

= 0 A – 4 A

Figure 3. TPS53125EVM-599 Efficiency vs Load Current

8

TPS53125EVM-599

SLVU392 – July 2010

Copyright © 2010, Texas Instruments Incorporated