Specification, 48 prosec t2n, Single-axis position control (continued) – Toshiba T2N User Manual
Page 63

2.Specification
48 PROSEC T2N
Input Circuit
Zero marker pulse input (5Vdc) : B5
Zero marker pulse input (0V) : A5
Normally Open-Contact Use
Zero marker pulse input (12/24Vdc) : B6
Zero marker pulse input (0V) : A6
B7
Origin position input (12/24Vdc)
A7
B11
CCW overtravel limit SW input (12/24Vdc)
A11
B10
CW overtravel limit SW input (12/24Vdc)
A10
B9
Emergency stop input (12/24Vdc)
A9
B8
HOLD input (12/24Vdc)
A8
Note : For the Zero marker pulse input use only one of
5Vdc or 12/24Vdc.
Normally Closed-Contact Use
Output Circuit
A1 : RUN output (0V)
B1 : RUN output
B12 : External power supply (12/24Vdc)
Constant-voltage circuit
A2 :CW pulse / pulse output (0V)
B2 : CW pulse / pulse output
A3 : CCW pulse / direction output (0V)
B3 : CCW pulse / direction output
A12 : External power supply (0V)
A4 : Error counter clear output (0V)
B4 : Error counter clear output
Single-Axis Position Control