Features, Part numbers – Telect MIX 56 User Manual

Page 12

Advertising
background image

1 Descriptions

MIX 56 User Manual

1-2

Telect, Inc. 122188-10 A0

Features

•

DSX and M13 in one chassis

•

Two fully independent systems per chassis, each with 28 DSX jacks
and up to two M13 cards, in a 5.25 inch (3 RU) rack space

•

Mounts in 19 inch (48.3 cm) or 23 inch (58.4 cm) WECO-spaced or
EIA-spaced racks

•

Multiplexes 28 DS1 or 21 E1 signals into one DS3 signal and demulti-
plexes a DS3 signal into 28 DS1 or 21 E1 signals

•

1:1 redundancy with second M13 card

•

Processor switching occurs in less than 50 ms

•

LED status indicators and tracer lamps on front panel

•

DSX jacks, tracer lamps, and alarm boards are field replaceable and
M13 cards are hot-swappable, all from the front of the chassis

•

Form-C critical, major, and minor external alarm contacts

•

Remote provisioning and monitoring through SNMP or two concurrent
Telnet

sessions

•

Separate alarm and event logs are rotating logs of up to 99 entries each

•

Selectable alarm thresholds

•

DS1 and DS3 loopback capabilities

•

BER Testing

•

DS3 signal format selectable between C-bit or M13 mode

•

C-Bit Remote Control to the MIX 56 at the other end of the DS3 link

•

DS1 line coding individually selectable between AMI or B8ZS for T1
and AMI or HDB3 for E1

•

Adjustable DS1 transmit line build out (LBO) for each channel

•

Automatic DS3 LBO

•

DS3 transmit clock source either recovered from DS3 receive signal or
by internal oscillator

•

Universal voltages: 20Vdc to 60Vdc

•

Three levels of user login security

Part Numbers

Part No.

Configuration

747-0000-2448

56 DSX Jacks, No M13 Cards

747-1103-2801

56 DSX Jacks, Two M13 Cards

747-1103-5601

56 DSX Jacks, Four M13 Cards

Advertising