Led panel – Telect MIX 56 User Manual

Page 15

Advertising
background image

MIX 56 User Manual

1 Descriptions

122188-10 A0

Telect, Inc.

1-5

LED Panel

NOTE

When a MIX 56 system used as a multiplexer is operating normally, the
High Speed and Low Speed LEDs on the LED panel and the active M13
card LED are all green. If the system is redundant, the standby card LED is
orange. Any LED configuration other than this indicates the system is not
operating normally.

LED

Status

Definition

Critical

Red

One or more critical alarms. (Two or more DSIs and/
or DS3 service affecting conditions.)

Unlit

No critical alarms

Major

Red

One or more major alarms. (DS1 or DS3 service im-
pacting condition.)

Unlit

No major alarms

Minor

Yellow

One or more minor alarms. Service processing and
traffic unaffected.

Unlit

No minor alarms

Maintenance

Yellow

Diagnostic tests are being performed; at least one
circuit is out of service

Unlit

No diagnostic tests are being performed

High Speed

Red

Receiving alarm indication signal (AIS) or experienc-
ing loss of signal (LOS) or out of frame (OOF) signal

Yellow

Receiving remote alarm indication (RAI)

Green

Operating normally

Unlit

Out of service or no power

Low Speed

Red

Receiving AIS or experiencing LOS

Green

Operating normally

Unlit

Out of service or no power

Alarm Cutoff (ACO)

Yellow

ACO is engaged

Unlit

ACO is not engaged

Minor

Major

Critical

Low Speed

High Speed

Maintenance

Alarm Cutoff

(ACO)

CRAFT

HS

CRT

MJR MNR MAINT

LS

ACO

ACO/LAMP