2.7 Display

2 Troubleshooting

Check 3

The FL may be faulty. Replace it with a new one and return to Procedure
3. If there is still an error, perform Check 4.

Check 4

The FL inverter board may be faulty. Replace it with a new one and
return to Procedure 3. If there is still an error, perform Check 5.

Check 5

Make sure the LCD/FL cable has been firmly connected to the system
board and LCD module.

FL inverter board

System board

CPU

LCD/FL cable


If the cable is loose or off, reconnect it firmly and return to Procedure 3.
If there is still an error, perform Check 6.

Check 6

The LCD/FL inverter cable may be faulty. Replace it with a new one and
return to Procedure 3. If there is still an error, perform Check 7.

Check 7

The LCD module may be faulty. Replace it with a new one and return to
Procedure 3. If there is still an error, perform Check 8.

Check 8

The System board may be faulty. Replace it with a new one. If there is
still an error, perform Check 9.

Check 9

The CPU may be faulty. Replace it with a new one following the
instructions in Chapter 4.

Check 10

The memory may be defective. Replace the memory module with a new
one following the steps described in Chapter 4. If the problem persist,
perform Check 10.