Tash limited 51150 User Manual

Page 9

Advertising
background image

9


4. Manual Calibrating Mode

When in manual calibrating mode, the activation distance is set by the user.

1. Turn the sensor box off.

2. Set the dip switches to:

SW3

Up

SW4

Down

3. Position the sensor.

4. Place the activating body part just beyond the desired activation
distance.

5. Turn the sensor box on.
6. Press the set switch beside the Dip Switches with the end of a pencil

until you hear three beeps and the valid light flashes three times.

7. The manual calibrating mode is now set.