Configuring the Modem 4-23

Confi

guring

the Modem

When used as a restoral device for Telenetics and Motorola 35XX DSU/CSUs
(Figure 4-1), select SDC Option Set 2 in the local and remote SDC Modems. This
places the modems in external timing, as digital services typically provide the network
timing.

Figure 4-1. Single Channel Point-to-Point Digital Link Restoral (A/B Switch)—Option Set 2

Note the following:

• With SDC Option Set 2 selected (for Telenetics, Motorola, non-Telenetics, and

non-Motorola DSU/CSUs), the DSUs’ restoral configuration should be set to
Timing=Internal.

• In this case, the 326XFAST-SDC DTE Rate must be set to a constant rate as

provided by the network (defaults of 56/64 kbps).

• Enable Option Set 2 in both the local and remote modems, and ensure that Mode

(AT

*

SM) is set the same in both modems.

• The SDC modem supports single channel environments only. For example, the

SDC modem can restore Port 1 only of the 35XX device.

• The 35XX device, when initiating restoral, must be set to Normal mode (as the

35XX network management channel is virtually a time division multiplexed data
stream which cannot be compressed with the SDC product).

• The SDC modem may have the ARS feature enabled. In this case, ARS

determines the link rate.

35XX

56/64 kbps

PSTN

Router

35XX

Router

To 33.6 kbps

NMS

Network Management Channel

To
56 kbps

326XFAST

SDC

326XFAST

SDC