4/24

SR-C8002 Rev.1.0

(10) Drawer Load/Release Load:

Manual

Release:

(a) Electrical Release (Release Button)

(b) Release by ATAPI command

(c) Emergency Release

(11) Air Flow

Not Required

(12) Acoustic Noise

40 dB (IEC 179 A weighted at 1 m)

(13) Power Supply

+5 V (details in Section 7)

3.2. Environmental Conditions

This drive should be used under the conditions listed below.

3.2.1.Temperature and Humidity

(1) Operating Temperature

5

°

C

to 50

°

C

*1

(2) Storage Temperature

-10

°

C

to 60

°

C

(3) Shipping Temperature

-40

°

C

to 65

°

C

*2

(4) Operating Temperature Gradient

11

°

C

/hour (max)

(5) Storage Temperature Gradient

20

°

C

/hour (max)

(6) Shipping Temperature Gradient

20

°

C

/hour (max) *2

(7) Operating Humidity

8 % to 80 %

(8) Storage Humidity

5 % to 95 %

(9) Shipping Humidity

5 % to 95 % *2

(10) Wet bulb Maximum Temperature

27

°

C

(11) Condensation

In all the above conditions there must be no condensation

*1: Except for disc
*2: Packed in Toshiba original shipping package.

3.2.2.Dust and Dirt

unspecified