Installation, Electrical installation – Thermador ME272 User Manual

Page 12

Advertising
background image

English 10

Installation

Electrical Installation

All model ovens on the front cover are dual rated, designed to be connected to
either 208/240V AC, 60 Hz, 4 wire, single-phase power supply.

The electrical supply should be a 4-wire single-phase AC. Install a suitable conduit
box (not furnished). An appropriately-sized, UL-listed conduit connector must be
used to correctly attach the conduit to the junction box.

Important: Local Codes may vary; installation, electrical connections and
grounding must comply with all applicable local codes.

If local codes permit grounding through the electrical supply neutral, connect both
the white neutral wire and the bare ground wire from the oven to the white neutral
electrical supply wire.

Model

Circuit Required

208V, 60 Hz

240V, 60 Hz

M271, M301

25 AMP

30 AMP

ME301, MEW301
ME271, PO301,
POD301, DE301,
DEC301

30 AMP

30 AMP

ME302, MED302,
ME272, MED272,
PO302, POD302,
PODC302, DE302,
MEM271, MEM301,
POM301, MEMC301,
MEMCW301,
MEMW271, MEMW301,
POMW301

40 or 50 Amp circuit. Refer to local electrical codes
for de-rating requirements.