27” under-the-counter units – Thermador ME272 User Manual

Page 7

Advertising
background image

English 5

Combo Oven with Microwave and
Warming Drawer 27”
It is good practice, when oven is
installed at the end of a cabinet run,
adjacent to a perpendicular wall or
cabinet door, to allow at least 1/4”
space between the side of the oven
and the wall/door.
For oven support, install 2x4’s
extending front to back flush with the
bottom and the side of the opening.
The supporting base must be well
secured to the floor/cabinet and level.
Note: The conduit box must be located
above the unit to facilitate connecting
and servicing.
The cabinet base must be flat and
capable of supporting a weight of at
least 370 lbs (168 kg).

36

"

(915mm)

20

"

(508mm)

28

1/4"

(718mm)

16

1/2"

(419mm)

24

"

(610mm)

4

3/4"

(121mm)

25

1/2"

(648mm)

23

7/8"

(606mm)

22

"

(559mm)

29

1/16"

(738mm)

26

3/4"

(680mm)

27

"

(686mm)

24

13/16"

(630mm)

min. 3

3/4"

(95mm)

27” Under-the-counter units